  The user must respect the requirements and precautions in the case of resupply by generating sets 

of  an  installation,  depending  on  existing  protective  measures  in  this  installation  and  applicable 

regulations. 

  Generating sets should only be loaded up to their rated power under the rated ambient conditions.  

 

Prior to commencing maintenance work it shall be ensured that untimely start-up is not possible.

 

 

1.3 SECURITY MEASURES WHEN FILLING THE FUEL TANK 

  The fuel is extremely flammable and poisonous. 

  This generator only uses petrol (gasoline); any other kind of fuel will damage the motor. 

  Do  not  overfill  the  tank  with  petrol  to  avoid  spilling.  If  you  notice  a  spill,  it  must  be  wiped  up 

completely with a dry cloth before starting the motor. 

  If you swallow fuel by mistake, if you inhale fuel vapors or if you get drops of fuel in your eyes, see a 

doctor immediately. If a certain quantity of fuel is spilt on your skin or clothing, wash or change your 

clothes. 

  Always stop the motor of the generator when filling it with fuel.  

  Never fill the fuel tank while smoking or near a naked flame. 

 

Make sure you don’t spill fuel on the motor and the exhaust grille of the generator during filling with 

fuel. 

  Keep the fuel in an appropriate recipient and sheltered from any sources of fire. 

  Carry out filling in a safe place, and slowly open the fuel cap to release the pressure which has built 

up inside the tank. Wipe up any drops of petrol that have spilled before starting the motor. 

  To prevent fire, move the generator at least 4 meters away from the area for filling with fuel. 

  Make sure that the fuel cap is tightly closed before starting. 

  Do not keep petrol in the tank for a long time. 

            While  using  or  transporting  the  generator,  make  sure  you  keep  the  generator  upright, 

otherwise the fuel may escape from the carburetor or the fuel tank. 

 

1.4 ELECTRICAL SAFETY  

  Before  each  use  ensure  that  the  load  to  be  connected  does  not  exceed  the  power  of  the  current 

produced by the generator. 

To avoid electric shock, you must follow the following instructions: 

  Do not touch the generator with wet hands. 

  Do not run the generator under rain or snow. 

  Do not run the generator near water. 

  Connect the generator to earth. Use a sufficiently thick conductor for the earth wire. 

  Do not operate the generator in parallel with another generator. 

  If using electrical extensions, make sure that they are sufficiently thick to transport the current and 

that they are used correctly. 

 

The  connection  of  a  generator  used  for  auxiliary  power  to  the  electrical  installation  of  a 

building  must  be  performed  by  a  qualified  electrician,  and  in  conformity  to  the  provisions  of  the 

Summary of Contents for FG3000-A

Page 1: ...ORIGINAL INSTRUCTIONS EN GASOLINE GENERATOR FG3000 A USER GUIDE CAUTION Read the instructions before using the product...

Page 2: ...5 GENERATOR USE 10 6 PRE OPERATION CHECK 13 7 STARTING STOPPING THE ENGINE 15 8 MAINTENANCE 16 9 TRANSPORTING AND STORAGE 20 10 TROUBLESHOOTING 22 11 WIRING DIAGRAM 23 12 SPECIFICATIONS 24 13 EC DECLA...

Page 3: ...ing area The operator or the user are responsible for possible accidents or damage to other persons or to their property Do not wear loose clothing or jewellery as this can get caught in the machinery...

Page 4: ...d cable with a strong rubber protective layer conforming to IEC 245 4 or a similar cable If using an electrical extension cable the total length of the extension must not exceed 60m when the section o...

Page 5: ...propriate recipient and sheltered from any sources of fire Carry out filling in a safe place and slowly open the fuel cap to release the pressure which has built up inside the tank Wipe up any drops o...

Page 6: ...o function with a voltage tolerance of 10 or a frequency tolerance of 3 compared with those of the generator 1 5 PROTECTION OF THE ENVIRONMENT You must periodically check the silencer Before doing thi...

Page 7: ...hock Exhaust emissions are harmful to health of body No naked fire near the machine This symbol indicates the surface is very hot and not touching 2 COMPONENT IDENTIFICATION NOTE Diagrams may vary acc...

Page 8: ...grip Place one handle on one side of the bar the holes must be aligned Screw it with a screw and a nut Do the same procedure on the other side 4 CONTROLS 4 1 ENGINE SWITCH To start and stop the engin...

Page 9: ...ture when starting a cold engine It can be opened and closed by operating the choke lever or choke rod manually Move the lever or the rod to the CLOSE position to enrich the mixture 4 5 CIRCUIT BREAKE...

Page 10: ...ction must isolate the generator power from utility power and must comply with all applicable laws and electrical codes WARNING Improper connections to a building s electrical system can allow electri...

Page 11: ...rating of the tool or appliance does not exceed that of the generator Never exceed the maximum power rating of the generator Power levels between rated and maximum may be used for no more than 30 minu...

Page 12: ...ed battery cable WARNING The battery gives off explosive gases keep spark flames and cigarettes away Provide adequate ventilation when charging or using batteries 2 Connect the positive battery cable...

Page 13: ...carburetor modification is made NOTICE If an engine jetted for high altitude is used at a lower altitude the lean air fuel mixture will reduce performance and may over heat and seriously damage the e...

Page 14: ...prolonged contact with skin or breathing of vapor KEEP OUT OF REACH OF CHILDREN Use gasoline with a pump octane rating of 86 or higher We recommend unleaded gasoline because it produces fewer engine...

Page 15: ...fuel are not ours responsibility and are not covered under warranty NOTICE Oxygenated fuels can damage paint and plastic Be careful not to spill fuel when filling your fuel tank Damage caused by spill...

Page 16: ...SCHEDULE REGULAR SERVICE PERIOD Performed at every indicated month or operating hour interval whichever comes first Each use First month or 20 Hrs 3 Every 3 months or 50 Hrs 3 Every 6 months or 100 H...

Page 17: ...and rapid draining 1 Remove the drain plug and sealing washer oil filler cap and drain the oil 2 Reinstall the drain plug and sealing washer Tighten the plug securely 3 Refill with the recommended oil...

Page 18: ...solvent NOTICE Never run the generator without the air cleaner Rapid engine wear will result 1 Unsnap the air cleaner cover clips remove the air cleaner cover and remove the element 2 Wash the elemen...

Page 19: ...ot Be careful not to touch the muffler 1 Remove the spark plug cap 2 Clean any dirt from around the spark plug base 3 Use the wrench supplied in the tool kit to remove the spark plug 4 Visually inspec...

Page 20: ...E PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required 1 to 2 months Fill with fresh gasoline and add gasoline conditioner 2 months to 1 year Fill with fresh gasoline and add g...

Page 21: ...At this point the piston is coming up on its compression stroke and both the intake and exhaust valves are closed Storing the engine in this position will help to protect it from internal corrosion Al...

Page 22: ...he plug cap 3 Set the plug side electrode on the cylinder head 4 Crank the engine sparks should jump across the gap YES YES Is the fuel reaching the carburetor Clean the fuel sediment cup If the engin...

Page 23: ...11 CIRCUIT DIAGRAM...

Page 24: ...kWh Lube Oil capacity L 0 6 L Sound pressure level LpA 74 dB A K 1 99 dB A Measured sound power level LwA 94 4 dB A K 1 99 dB A Guaranteed sound power level 96 dB A Generator SET Generator set AC out...

Page 25: ...30 EU ROHS Directive EU 2015 863 amending 2011 65 EU Noise directive 2000 14 CE Annex VI 2005 88 CE Also complies with European standards with national standards and the following technical provisions...

Page 26: ...the user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifcations without notice Consequently the product may be diferent from the information c...

Page 27: ...epairs will be done by approved engine manufacturers of these manufacturers see their site http www briggsandstratton com eu fr http www honda engines eu com fr service network page jsessionid 5EE8456...

Page 28: ...ssary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate by a SWAP Europe repair sta...