Step 1B - Drill Posts and Route Starter Cable

Determine the post that will act as the star  ng post, this will likely 
be designated on the ligh  ng layout schema  c received with the 
order.  Installing the starter cable through the post is easiest when 
done prior to moun  ng the post

.

Determine the loca  on that the starter cable will enter the star  ng 
post. 

Note: Depending on the post moun

 ng method, and driver loca

 on 

rela

 ve to the post, the starter cable entrance point may vary. (See 

Figure 1.2 for typical recommenda

 ons)

Figure 1.1

1/2" DIA.

HOLE

GROMMET

PART #1114

WIRE COMES 
UP THROUGH 
DECKING AND 
INTO POST.

WIRE CAN BE RUN 
IN CONDUIT BURIED 
IN CONCRETE, OR 
RUN DIRECTLY 
FROM ENCLOSURE 
TO POST. WIRE 
INSIDE POST RUNS 
BETWEEN INSIDE 
POST WALL AND 
STANCHION.

WIRE RUNS UNDER 
DECK THROUGH 
FASCIA BOARDS 
AND ENTERS POST 
BELOW DECKING 
SURFACE BETWEEN 
FACSIA AND POST 
FACE.

WIRE RUNS 
UNDER DECK AND 
ENTERS POST 
ABOVE FASICA 
BRACKET BELOW 
DECKING.

WIRE RUNS UNDER 
DECK THROUGH 3/4" 
HOLE IN BASEPLATE 
AND BLOCKING. 

(3/4" HOLE DRILLED BY 
CUSTOMER)

Figure 1.2

For systems with Series 200, 300, 350, or 450 top rail:

 

Fish the connector for the starter cable through the post and out 
of the top, and a  ach LED 2-Way Spli  er to Starter Cable 

(See 

Figure 1.3).

IMPORTANT NOTE:  

Maintaining the polarity at all connec-

 on points is cri  cal.  Constant alignment veri

fi

 ca  on 

of the of the posi  ve and nega  ve signs  will guarantee 
less problems and rework. 

Use masking tape to temporarily secure starter cable to outside 
of post to prevent retrac  ng back into post.

2-WAY 
SPLITTER

STARTER CABLE

Figure 1.3

MALE CONNECTOR 

FEMALE CONNECTOR

Keep the straight line 
on the outside ma

 ng 

connec

 on aligned

Summary of Contents for DesignRail LED 40W-DK

Page 1: ...Ligh ng DesignRail LED Ligh ng may not be suitable for every applica on and it is the sole responsibility of the installer to ensure that DesignRail LED Ligh ng is used for its intended purpose WARNING ELECTRIC SHOCK IS ALWAYS POSSIBLE WHEN WORKING WITH ELECTRICITY THIS CAN CAUSE SERIOUS PERSONAL INJURIES OR DEATH ELECTRICAL SHORTS CAN ALSO CAUSE FIRES AND PROPERTY DAMAGE ALWAYS MAKE SURE THE ELEC...

Page 2: ...x Wire Nuts Pair 1x Isola on Bushing 60W Driver Kit SKU LED 60W DK 1x 60 Wa Dimmable Driver 1x Starter Cable 20 1x Wire Nuts Pair 1x Isola on Bushing 96W Driver Kit SKU LED 96W DK 1x 96 Wa Dimmable Driver 1x Starter Cable 20 1x Wire Nuts Pair 1x Isola on Bushing LED 2 WAY SPLITTER SKU LED 2WAY LED EXTENSION CABLE 132 SKU LED EXT132 LED STARTER CABLE 20 SKU LED STC Post Accent Light Components LED ...

Page 3: ...le to the lighࢼng to reduce the possibility of voltage drop occuring If possible the driver should be within 15 feet of the post that will accept the 20 starter cable Route exterior rated wiring from compa ble dimmer switch AC power source to loca on of driver Connect drivers to dimmer switch AC power source Connect 20 starter cable and route from driver to post using supplied wire nuts Step 1 Ins...

Page 4: ... BETWEEN INSIDE POST WALL AND STANCHION WIRE RUNS UNDER DECK THROUGH FASCIA BOARDS AND ENTERS POST BELOW DECKING SURFACE BETWEEN FACSIA AND POST FACE WIRE RUNS UNDER DECK AND ENTERS POST ABOVE FASICA BRACKET BELOW DECKING WIRE RUNS UNDER DECK THROUGH 3 4 HOLE IN BASEPLATE AND BLOCKING 3 4 HOLE DRILLED BY CUSTOMER Figure 1 2 For systems with Series 200 300 350 or 450 top rail Fish the connector for...

Page 5: ...ll 1 2 diameter hole Pull one branch of the LED 2 way spli er out through drilled hole between RCB holes and a ach LED Extension Cable to the other branch See Figure 1 5 IMPORTANT NOTE Maintaining the polarity at all con nec on points is cri cal Constant alignment verifi ca on of the of the posi ve and nega ve signs will guarantee less problems and rework Use masking tape to temporarily secure sta...

Page 6: ... Series 200 300 350 or 450 top rail String an extension cable between each post and connect a 2 way spli er Feed one branch of the spli er out through the 1 2 lead wire pilot hole drilled in the previous step this becomes the lead wire for the light at this post Feed the other branch of the 2 way spli er over the top of the post and connect an extension cable See Figure 2 3 Note A 2 way spli er do...

Page 7: ...he spli er out through the 1 2 lead wire pilot hole drilled in the previous step this becomes the lead wire for the light at this post Feed the other branch of the 2 way spli er through the 1 2 hole and the hollow of the RCB and connect an extension cable See Figure 2 4 Note A 2 way spli er does not need to be used at the final post as the extension cable will connect to the final light to complet...

Page 8: ...the moun ng plate by inser ng back plate into angled receiver flanges on moun ng plate See Figure 3 4 Step 3D Secure Lens Secure the lens and the moun ng plate to the post using two of the provided 8 x 3 4 self tapping screws See Figure 3 5 Step 3E A ach Cover A ach the cover onto the moun ng plate by aligning the tabs on the cover with the slot on the sides of the moun ng plate and sliding the co...

Page 9: ... Figure 4 1 Step 4B Adjust LED Array Bracket Slide the LED array bracket up or down to acheive desired light aperture See Figure 4 2 Step 4C Tighten LED Array Bracket Once the LED array bracket is in the desired loca on ghten the nut on the LED array bracket See Figure 4 3 Step 4D Re a ach Cover Slide the cover down un l it comes in contact with the lens See Figure 4 4 Figure 4 1 Figure 4 2 Figure...

Page 10: ... on AC circuit breaker 5 Power up the driver and check all LED loca ons for illumina on Scenario 2 Some LED locaঞons are illuminated but others are not 1 Note which loca ons are not illumina ng 2 Turn off AC circuit breaker prior to con nuing to next procedure 3 Rotate the connector 180 degrees at each noted loca on where the array is not illumina ng 4 Repeat at all noted loca ons that did not illu...

Page 11: ...www feeneyinc com 1 800 888 2418 2021 Feeney Inc 10 21 ...

Reviews: