CX SERIES Installation, Operating & Maintenance Manual
INST
ALLER
CONTROL DIMENSIONS
Ethernet Connection
Power Connection
•
Locate sensor on a wall inside the
steam room five (5) feet above the
floor.
DO NOT LOCATE THE SENSORS
NEAR OR ABOVE THE
STEAMHEAD(S) AS THIS MAY
CAUSE DIRECT STEAM EMISSION
TO INTERFERE WITH STEAM-ROOM
TEMPERATURE REGULATION.
•
Route sensor cable directly to PLC in
the primary generator as shown.
•
Do not route sensor cable with power wiring next to electric
motors or any other location subject to electrical noise.
•
Seal cable entrance to steam room with silicone.
•
Protect sensor with bulb guard provided.
Ensure all splices in the sensor cable are securely
crimped or soldered and sealed with heat shrink tubing.
Sensor Cable
1" hole
Silicone Sealant
(4) Mounting Screws
Bulb Guard
Route Se
nsor
Cable dire
ctly
to Digita
l 1 Contro
l
Locate approximately
5 feet above
steam room floor
Sensor
DIAGRAM
A
TEMPERATURE SENSOR INSTALLATION