CX SERIES Installation, Operating & Maintenance Manual
CONTROL MOUNTING
•
Select the mounting plate or box for either flush or
surface mounting respectfully.
FLUSH MOUNTING
•
Cut a 5 7/8” wide by 7 5/8” tall hole into the wall.
•
Insert the control into the provided mounting plate.
•
Insert and tighten each of the 4 provided clips into
their respective slots on the sides and top of the
control to secure the control to the mounting plate.
•
Insert the control into the new hole in the wall.
•
Take note that the wire connections and the light on
the front face of the control should be facing down.
•
Using the provided screws and wall anchors, secure
the mounting plate to the wall.
SURFACE MOUNTING
•
Insert the control into the provided mounting box.
Take note that the wire connections and the light on
the front face of the control should be facing down,
as does the side of the box which is open.
•
Insert and tighten each of the 4 provided clips into
their respective slots on the sides and top of the
control to secure the control to the mounting box.
•
Using the provided screws and wall anchors, secure
the mounting box to the wall.
CONTROL ELECTRICAL
•
The control must be plugged into a 120 VAC outlet
GENERATOR ELECTRICAL
•
Connect power wiring to main terminal block.
•
Open the Terminal cover on the right side of the
generator.
•
Connect the 30 minute room timer, and the
emergency stop, diagram below. The 30 minute
room timer and the emergency stop are optional. A
jumper between the L and S terminals will need to
be removed to install the room timer. Please see the
appropriate wiring diagram for more details. If this
room does not use either options, no changes are
needed.
•
In the event the CX system has multiple generators,
connect the 30 minute room timer, the emergency
stop, and the room probe to generator 1.
EXTERNAL TERMINAL CONNECTIONS