5
NETWORK CONNECTION...
There are 3 factory fitted communication op-
tions, Ethernet, serial and 802.11g wireless.
The serial terminal has both RS485 and
RS232 built
-
in, and can be configured to use one or the other. The Ethernet terminal is
fitted with a 10/100BaseT interface.
The terminal is fitted with a single RJ45 8
-
pin connector suitable for standard CAT5 or
equivalent unshielded twisted pair (UTP) cable. It is used for all communications and net-
work connections.
The RJ45 connections are as follows:
The connector is mounted in the back of the terminal, with the cable exiting horizontally.
If the terminal is in the middle of a RS485 network, it will be necessary to connect both
incoming and outgoing cables to the same connector. This can be easily achieved using
a standard flush or surface mounted RJ45 outlet with a short patch lead to connect it to
the terminal.
NETWORK CONNECTION CABLE ASSEMBLIES...
There are cable assem-
blies available from Feedback for the various network configurations. They are as follows:
PPU
-
ETHRN
-
ADP
-
Ethernet UTP network outlet to TR
-
1000 with Ethernet capability.
PPU
-
RS232
-
ADP
-
A 9 Way D type socket to TR
-
1000 utilising RS232 3 wire comms i.e.
Tx, Rx & Gnd only.
PIN
1
2
3
4
5
6
7
8
Wire
W/O
O
W/GN
BL
W/BL
GN
W/BN
BN
Ethernet
Tx+
Tx
-
Rx+
Rx
-
Modem
NC
NC
NC
TIP
RING
NC
NC
NC
RS485
0V
Tr+
+V
+V
Tr
-
0V
RS232
Tx
0V
+V
+V
Rx
0V
CONNECTING THE TERMINAL TO THE NETWORK