background image

INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT™

STATUS INDICATOR MODEL USI

SAFETY NOTICES

Failure to follow all safety precautions and instructions may result in
property damage, serious injury, or death to you or others.

 SAFETY MESSAGE TO INSTALLERS, USERS, AND MAINTENANCE PERSONNEL

It is important to follow all instructions shipped with this product. This device is

to be installed by a trained electrician who is thoroughly familiar with and will follow
all applicable national and local codes.

This device may be considered a part of the signaling system and not the entire

signaling system.

The selection of the mounting location for the device, its controls and the routing

of the wiring is to be accomplished under the direction of the facilities engineer. In
addition, listed below are some other important safety instructions and precautions you
should follow:

 Read and understand all instructions before installing or operating this
equipment.

 Do not connect this light to the system when power is on.

 After installation, ensure that all screws and threaded joints are
properly tightened.

 After installation, test the light system to ensure that it is operating
properly.

 After testing is complete, provide a copy of this instruction sheet to all
operating personnel.

 Establish a procedure to routinely check the light installation for
integrity and proper operation.

I.

GENERAL.

The UniStat™  (USI) is a TYPE 4X with IP66  rating and the UniStat™  (USIS) is

a TYPE 1  status indicator for indoor use that is compact in size. Each UniStat™ status
indicator contains one base, sleeve, PCB, color LED array, lens, cap, and surface gasket.
The cap and sleeve attach to each end of the lens by twist lock joint. Two screws hold
the base and sleeve together. An O-ring between each module provides a water-tight
and dust-tight seal except for the USIS models which has slots to allow audio to emit
from the unit.

A printed circuit board runs the entire length of the base and sleeve of the

UniStat™ status indicator. The printed circuit board contains a terminal block and
circuitry for the control of a color LED array that has an average life of 100,000 hours.
The terminal block provides connection for two input power lines and eight terminals
for setting the operating modes.

-1-

Summary of Contents for UNISTAT USI Series

Page 1: ...MODELO USI DE FEDERAL SIGNAL MOD LES USI 024 USIS 024 USI 120 ET USIS 120 FEUILLET D INSTRUCTION POUR LE MOD LE FEDERAL SIGNAL UNISTAT INDICATEUR DE STATUT MOD LE USI Address all communications and s...

Page 2: ...ure that all screws and threaded joints are properly tightened After installation test the light system to ensure that it is operating properly After testing is complete provide a copy of this instruc...

Page 3: ...ase Model MSTB II INSTALLATION A Unpacking After unpacking the equipment examine it for damage that may have occurred in transit If the equipment has been damaged do not attempt to install or operate...

Page 4: ...the four mounting holes and the center clear ance hole d Drill the four mounting holes using a 34 drill In the center of the 4 hole pattern drill the large clearance hole using a 1 hole saw e Knock ou...

Page 5: ...selection 5 Before reassembling make sure the O ring is in place between the base and sleeve To reassemble the base unit first attach the sleeve onto the base by sliding the printed circuit board int...

Page 6: ...CB USI 024QC K2005347 PCB USIS 024QC K2005347 01 PCB USI 120TC K2005347 02 PCB USIS 120TC K2005347 03 PCB USI 120QC K2005347 02 PCB USIS 120QC K2005347 03 TC LED PCB K2005328 QC LED PCB K2005328 01 Fu...

Page 7: ...Green LED O O X O O X Alternating Amber Red Colors O X X O O X Slow Flash Alternating Amber Red Colors X O X O O X SimuStrobe Alternating Amber Red Colors X X X O O X Strobe Flash Amber Red Colors O...

Page 8: ...dos los tornillos y las uniones roscadas est n apretadas firmemente Despu s de la instalaci n pruebe el sistema de luz para asegurarse que est funcionando correctamente Despu s de completar la prueba...

Page 9: ...tubo de 3 4 NPT Tres extensiones de tubo modelos MSP 4 MSP 16 y MSP 32 precortadas en longitudes de 4 16 y 32 respectivamente roscadas y pintadas est n disponibles para usar con la base de tulip n mo...

Page 10: ...es UniStat a Retire el lente girando en contra del sentido de las agujas del reloj como se ve de encima hasta que se desbloquee Levante el lente hacia arriba retir ndolo de la unidad conserve el O rin...

Page 11: ...do de f brica Si la unidad no ha sido desensamblada previamente para montaje realice los pasos siguientes Consulte la figura 1 para informaci n adicional 1 Retire el lente girando en contra del sentid...

Page 12: ...a arse de una Autorizaci n de devoluci n de material RMA Puede obtener esta RMA del Distribuidor o Representante del fabricante local En este punto debe darse una breve explicaci n del servicio solici...

Page 13: ...robosc pico con destello O O X O O X Alternando colores mbar rojo O X X O O X Destello lento alternando colores mbar rojo X O X O O X SimuStrobe alternando colores mbar rojo X X X O O X Colores mbar r...

Page 14: ...taller et de faire fonctionner cet quipement Ne branchez pas ce dispositif au syst me lorsque l alimentation est en marche Une fois l installation termin e asurez vous que toutes les vis de r glage et...

Page 15: ...e tableau 1 identifie les connexions des bornes et les modes de fonctionnement pour les mod les UniStat TC et QC La base de l UniStat peut tre mont e sur une surface ou sur un tuyau NPT de 3 4 po Une...

Page 16: ...une plus grande visibilit au signal visuel Les consignes d installation de cette seconde option de montage sur surface sont four nies avec les accessoires de montage du UniStat en option a Retirez la...

Page 17: ...Connexions lectriques Le UniStat vous est livr assembl en usine Si l appareil n a pas d j t d sassembl pour le montage proc dez selon les tapes suivantes Consultez la figure 1 pour de plus amples info...

Page 18: ...pection ou r paration doivent tre accom pagn s d une autorisation de retour de mat riel RMA Ce RMA peut tre obtenu de votre distributeur local ou du repr sentant du fabricant C est ce moment que vous...

Page 19: ...clair O O X O O X Alternance couleurs orange rouge O X X O O X clair lent et alternance couleurs orange rouge X O X O O X SimuStrobe et alternance orange rouge X X X O O X Stroboscope clair couleurs...

Page 20: ...ar G Cap Espa ol A Base B Anillo t rico C Tarjeta de circuitos impresos D Forro E Tornillo Phillips 6 F Lente transparente G Tapa Fran ais A Base B Joint torique C Plaquette de circuits imprim s D Man...

Page 21: ...2 290A4142 7 765 197 231mm 2 200 55 880mm 20...

Page 22: ...3 21 290A4143C A G R SEL A B L N F S AL...

Page 23: ...CA 10 L L nea CC CA PRECAUCI N NO CONECTE EL PIN 4 al PIN 9 Conecte el PIN 4 a cualquiera de los PINES 1 2 3 5 6 7 o 8 directo o seleccione cualquiera mediante el interruptor de contacto cerrado Al c...

Page 24: ...2561673D REV D Printed 8 06 Printed in U S A...

Reviews: