background image

from the unit before surface mounting. To disassemble the UniStat™ follow the steps
below. Reference figure 1 for additional information.  Alternatively, the UniStat™ may
be surface mounted using the UniStat mounting accessories, Tulip Base (Model MSTB)
with a Pipe Extension (MSP-4, MSP-16 or MSP-32). These optional mounting accesso-
ries allow the UniStat lens to be elevated to overcome visual obstacles in the room for
greater visibility of the visual signal. Installation instructions of this second surface
mounting option are provided with the optional UniStat™ mounting accessories.

a.

Remove the lens by twisting counter-clockwise (as viewed from the

top) until it unlocks. Lift the lens upward and off the base unit, retain O-ring.

b.

Remove the two Phillips head #6 screws and disassemble the sleeve

from the base. The printed circuit board with LED array will remain attached to the
sleeve allowing access to the terminal block. Retain O-ring for sleeve.

c.

Use the surface-mounting gasket as a template to determine the

mounting location of the unit. d. Mark the four mounting holes and the center clear-
ance hole.

d.

Drill the four mounting holes using a #34 drill. In the center of the

4-hole pattern, drill the large clearance hole using a 1" hole saw.

e.

Knock out the four surface mount holes at the bottom of the base.

f.

Postion the gasket on the surface and place the base on top of the

gasket. Secure the base with the appropriate #6 screws.

Excessive torque on the mounting screws may crack the base. Do not over
tighten the screws.

C.

Specifications.

USI-024 AND USIS–024

USI-120 AND USIS-120

Operating Voltage Range

24VDC

100-240VAC 50-60 Hz

Operating Current

0.100A

 0.060A

Operating Temperature

 +32

°

 to 104

°

 F (0

°

  to 40

°

 C) +32

°

 to 104

°

 F (0

°

  to 40

°

 C)

Dimensions

Refer to figure 2

Refer to figure 2

Flash Rate: 400ms “ON”, 400ms “OFF”
Strobe Rate: 50ms “ON”, 20ms “OFF”
Alternating Colors: Each color is “ON” 400ms with 70ms delay between colors.
Slow Flash Alternating Colors: Each color is “ON” 400ms with 400ms delay between
colors.
Simu Strobe Alternating Colors: Each color is strobed 5 pulses 50ms “ON”, 20ms “OFF”
with 50ms delay between colors.
Strobe/Flash Alternating Colors: Each color is strobed 5 pulses 50ms “ON”, 20ms “OFF”

Environmental Ratings:
a. USI-024 and USI-120 are TYPE 4X Indoor, IP66
b. USIS-024 and USIS-120 are TYPE 1 Indoor

-3-

Summary of Contents for UNISTAT USI Series

Page 1: ...MODELO USI DE FEDERAL SIGNAL MOD LES USI 024 USIS 024 USI 120 ET USIS 120 FEUILLET D INSTRUCTION POUR LE MOD LE FEDERAL SIGNAL UNISTAT INDICATEUR DE STATUT MOD LE USI Address all communications and s...

Page 2: ...ure that all screws and threaded joints are properly tightened After installation test the light system to ensure that it is operating properly After testing is complete provide a copy of this instruc...

Page 3: ...ase Model MSTB II INSTALLATION A Unpacking After unpacking the equipment examine it for damage that may have occurred in transit If the equipment has been damaged do not attempt to install or operate...

Page 4: ...the four mounting holes and the center clear ance hole d Drill the four mounting holes using a 34 drill In the center of the 4 hole pattern drill the large clearance hole using a 1 hole saw e Knock ou...

Page 5: ...selection 5 Before reassembling make sure the O ring is in place between the base and sleeve To reassemble the base unit first attach the sleeve onto the base by sliding the printed circuit board int...

Page 6: ...CB USI 024QC K2005347 PCB USIS 024QC K2005347 01 PCB USI 120TC K2005347 02 PCB USIS 120TC K2005347 03 PCB USI 120QC K2005347 02 PCB USIS 120QC K2005347 03 TC LED PCB K2005328 QC LED PCB K2005328 01 Fu...

Page 7: ...Green LED O O X O O X Alternating Amber Red Colors O X X O O X Slow Flash Alternating Amber Red Colors X O X O O X SimuStrobe Alternating Amber Red Colors X X X O O X Strobe Flash Amber Red Colors O...

Page 8: ...dos los tornillos y las uniones roscadas est n apretadas firmemente Despu s de la instalaci n pruebe el sistema de luz para asegurarse que est funcionando correctamente Despu s de completar la prueba...

Page 9: ...tubo de 3 4 NPT Tres extensiones de tubo modelos MSP 4 MSP 16 y MSP 32 precortadas en longitudes de 4 16 y 32 respectivamente roscadas y pintadas est n disponibles para usar con la base de tulip n mo...

Page 10: ...es UniStat a Retire el lente girando en contra del sentido de las agujas del reloj como se ve de encima hasta que se desbloquee Levante el lente hacia arriba retir ndolo de la unidad conserve el O rin...

Page 11: ...do de f brica Si la unidad no ha sido desensamblada previamente para montaje realice los pasos siguientes Consulte la figura 1 para informaci n adicional 1 Retire el lente girando en contra del sentid...

Page 12: ...a arse de una Autorizaci n de devoluci n de material RMA Puede obtener esta RMA del Distribuidor o Representante del fabricante local En este punto debe darse una breve explicaci n del servicio solici...

Page 13: ...robosc pico con destello O O X O O X Alternando colores mbar rojo O X X O O X Destello lento alternando colores mbar rojo X O X O O X SimuStrobe alternando colores mbar rojo X X X O O X Colores mbar r...

Page 14: ...taller et de faire fonctionner cet quipement Ne branchez pas ce dispositif au syst me lorsque l alimentation est en marche Une fois l installation termin e asurez vous que toutes les vis de r glage et...

Page 15: ...e tableau 1 identifie les connexions des bornes et les modes de fonctionnement pour les mod les UniStat TC et QC La base de l UniStat peut tre mont e sur une surface ou sur un tuyau NPT de 3 4 po Une...

Page 16: ...une plus grande visibilit au signal visuel Les consignes d installation de cette seconde option de montage sur surface sont four nies avec les accessoires de montage du UniStat en option a Retirez la...

Page 17: ...Connexions lectriques Le UniStat vous est livr assembl en usine Si l appareil n a pas d j t d sassembl pour le montage proc dez selon les tapes suivantes Consultez la figure 1 pour de plus amples info...

Page 18: ...pection ou r paration doivent tre accom pagn s d une autorisation de retour de mat riel RMA Ce RMA peut tre obtenu de votre distributeur local ou du repr sentant du fabricant C est ce moment que vous...

Page 19: ...clair O O X O O X Alternance couleurs orange rouge O X X O O X clair lent et alternance couleurs orange rouge X O X O O X SimuStrobe et alternance orange rouge X X X O O X Stroboscope clair couleurs...

Page 20: ...ar G Cap Espa ol A Base B Anillo t rico C Tarjeta de circuitos impresos D Forro E Tornillo Phillips 6 F Lente transparente G Tapa Fran ais A Base B Joint torique C Plaquette de circuits imprim s D Man...

Page 21: ...2 290A4142 7 765 197 231mm 2 200 55 880mm 20...

Page 22: ...3 21 290A4143C A G R SEL A B L N F S AL...

Page 23: ...CA 10 L L nea CC CA PRECAUCI N NO CONECTE EL PIN 4 al PIN 9 Conecte el PIN 4 a cualquiera de los PINES 1 2 3 5 6 7 o 8 directo o seleccione cualquiera mediante el interruptor de contacto cerrado Al c...

Page 24: ...2561673D REV D Printed 8 06 Printed in U S A...

Reviews: