![Federal Signal Corporation UltraVoice UVIC Description, Specifications, Installation, Operation, And Service Manual Download Page 54](http://html1.mh-extra.com/html/federal-signal-corporation/ultravoice-uvic/ultravoice-uvic_description-specifications-installation-operation-and-service-manual_3832936054.webp)
54
Operations
UltraVoice Indoor Controller (UVIC)
Manual Activation
Use the manual activation switches to activate siren functions. Switches are located on
the face of the controller. In addition, activating switches simultaneously can operate
specific testing and calibration features. See Table 40.
Figure 13 UV+ Controller Card Switches
Table 40 Manual Activation Switches on UV+ Controller Card
Function Switch
Function
CODE 1
Activates function 1
CODE 2
Activates function 2
CODE 3
Activates function 3
CODE 4
Activates function 4
CODE 5
Activates function 5
CODE 6
Activates function 6
CODE 7
Activates function 7
STOP
Reset
CODE 1 and CODE 6 Loads default speaker calibration values and transmits DTMF
characters (production testing)
CODE 2 and CODE 3 Calibrate speaker load and Xmit DTMF Quiet Test
CODE 5 and CODE 7 Transmits 1200 Hz tone for radio deviation adjustment
NOTE:
At any time during a sounding function, push the RESET button to cause the unit
to halt all output immediately.
Local Public Address
With the optional microphone (part number MNC-MC), the operator has the ability to
locally give a Public Address (PA) message. You can enter the PA mode by plugging the
MNC-MC into the microphone receptacle labeled MIC on the controller card front panel.
The PA LED is lit anytime the press-to-talk (PTT) button on the microphone is pressed.