![Federal Signal Corporation UltraVoice UVIC Description, Specifications, Installation, Operation, And Service Manual Download Page 46](http://html1.mh-extra.com/html/federal-signal-corporation/ultravoice-uvic/ultravoice-uvic_description-specifications-installation-operation-and-service-manual_3832936046.webp)
46
Operations
UltraVoice Indoor Controller (UVIC)
1, 2, 4, 8, 16, 32, 64, 128 256, 512. Add appropriate dip switch values to define the site
number address.
Example
To define the board for Site #1 toggle first dip switch to the left. All other dip switches
are to the right. For Site #2 toggle the second dip switch to the left. For Site #3 toggle the
first and second dip switch to the left. For Site #4 toggle the third dip switch to the left.
For Site #5 toggle the first and third dip switch to the left. Continue this method to define
other site number addresses.
Figure 10 Setting the Switch Number Example
Switch number 1
2 3
4
5
6
7
8
9
10
Binary number 1
2 4
8
16
32 64 128 256 512
Example: Switch numbers 1, 2, and 3 are binary numbers 1, 2, and 4.
Add 1 + 2 + 4 = 7; 7 is the unit address
NOTE
: Programming details are in the software manual. The site address is stored at
power up of the controller. If the site address is changed, the power (battery and AC)
must be turned off and then on.