![Federal Signal Corporation UltraVoice UVIC Description, Specifications, Installation, Operation, And Service Manual Download Page 44](http://html1.mh-extra.com/html/federal-signal-corporation/ultravoice-uvic/ultravoice-uvic_description-specifications-installation-operation-and-service-manual_3832936044.webp)
44
Operations
UltraVoice Indoor Controller (UVIC)
User Programs
The UVIC controller has the capacity to store up to fifty user programs. Each user
program contains
twenty
stacked function items.
Assigning more than one function to each activation code or user program allows you to
run a sequence of functions without sending additional activation commands.
Activation Functions
Table 31 Activation Functions
Function
Definition
Arm
Arms the siren.
Disarm
Disarms the siren.
Wail
Sound Wail siren tone.
Pulsed Wail
Sound Pulsed Wail siren tone.
Alternate Wail
Sound Alternate Wail siren tone.
Steady
Sound Steady siren tone.
Pulsed Steady
Sound Pulsed Steady siren tone.
Alternate Steady
Sound Alternate Steady siren tone.
Auxiliary (Chime)
Sound Auxiliary siren tone. The Auxiliary tone is normally set for
Westminster Chimes.
Digital Voice
(1-250 DV
messages)
Enter the desired digital voice number to run and click OK. If voice
number is not between 1 and 250, an error message box appears.
Dynamic Voice
Plays a sequence of digital voice messages specified at the time of
activation. This function is only applicable for sirens equipped with a
special vocabulary chip.
Public Address
Broadcast live radio PA. PA remains active until carrier has dropped
for ten seconds or 4 1/2 minutes, whichever occurs first.
Play Recorded PA Play message previously recorded during the “RECORD PA” function.
For EAS activation, the message repeats continuously for the duration
of time encoded in the TTTT field. For non-EAS activation, the “PLAY
RECORDED PA” function plays once without repeats.
Quiet Test
Performs a self-test of the siren’s amplifiers and speakers by sounding
a 20 kHz tone.
Cancel
Terminates active function.
Report
Send unit status to base.
Master Reset
Terminates active function and clears latched status.
Plus Phase
All functions between “PLUS PHASE” and “MINUS PHASE” repeat
for the duration of time encoded in the EAS activation frame (EAS
activations only).
Minus Phase
All functions between “PLUS PHASE” and “MINUS PHASE” repeat
for the duration of time encoded in the EAS activation frame (EAS
activations only).
Phase Off
Turn off minus and plus phase and return siren to omni directional
mode.