![Federal Signal Corporation UltraVoice UVIC Description, Specifications, Installation, Operation, And Service Manual Download Page 24](http://html1.mh-extra.com/html/federal-signal-corporation/ultravoice-uvic/ultravoice-uvic_description-specifications-installation-operation-and-service-manual_3832936024.webp)
24
Installation
UltraVoice Indoor Controller (UVIC)
General Mounting Guidelines For All Applications
These general installation instructions are pertinent to all installations. Specific mounting
methods and required installation materials are described in the next section.
1. There are three pre-drilled holes in each of the cabinet mounting flanges. (See
Figure 3 UVIC Cabinet Dimensional Outline Drawing.) Depending on the mounting
surface, mount the cabinet using either of the following sets of holes:
• (2) Centered 0.41 inch diameter mounting holes
• (4) Mounting slots 0.41 by 2 inches with 12 to 16 inches centers
2. The total weight of the UVIC cabinet with batteries is listed in the Specifications
section. It is imperative that the mounting surface and mounting method selected can
safely sustain the weight of the assembly. To reduce the weight of the cabinet during
installation, do not install the batteries before mounting the cabinet.
3. Prepare the mounting surface for hanging the cabinet by predetermining the location
of the mounting holes. Attach the cabinet to a wall or other substantial vertical
surface using the four 0.41 inch mounting slots. Alternatively, use the two center
mounting holes alone, if securely lagged directly into a wood stud or other vertical
surface capable of handling the weight load.
If the mounting surface is not flat, the cabinet may require shimming to keep the
cabinet square.
4. Guidelines for various attachment methods to accommodate different wall types are
described in the following section. Make provisions for spacing behind the cabinet
when mounting to an exterior wall that is susceptible to condensation or other surface
moisture.
5. With the two batteries removed, use two people to lift the cabinet to the desired
mounting height and lag to the wall using the prepared holes and anchors.