ELECTROSTATIC HAZARD: The VoIP PCBA is susceptible to damage from electrostatic discharge (ESD) and is 

protected by a metal shield. If it is necessary to remove the shield, take suitable precautions.

SHOCK HAZARD: If using an auxiliary power supply, ensure that it is unplugged during installation to avoid an 

accidental shock or circuit damage.

NOTES: 

• 

Determine if power to operate the telephone will be provided via the Ethernet or if external power will be required. If 

external power is required, install an auxiliary power supply

• 

To maintain Ingress Protection / NEMA ratings, use appropriately rated hardware and waterproofing techniques.

• 

Choose a wall location that is free of obstructions and permits space for conduit runs.

• 

Ensure that mounting can support 7 lb (3.2 kg) and any additional foreseeable load.

To install the telephone:

1. 

Separate the faceplate from the housing.

2. 

Use the template provided or the enclosure itself to locate and drill holes for the mounting screws.

3. 

Secure the unit to the wall with user-supplied 1/4

"

 or M8 screws.

4. 

Bring the network cable into the enclosure through the conduit entrance and plug into the RJ-45 connector on the 

PCBA. See Figure 4.

Summary of Contents for FT100C-V

Page 1: ...installed by a licensed electrician according to all electrical and building codes WARNING DISLOCATION HAZARD To prevent injury this apparatus must be securely attached to the floor or wall in accord...

Page 2: ...ble communication in areas prone to high humidity chemical vapors dust and physical abuse The FT100C V Telephone is compatible with most SIP based IP PBX servers that comply with SIP RFC 3261 Users ca...

Page 3: ...udio files Event Monitoring Triggers Refer to VoIP Configuration Guide Part Number 25500857 Peer to peer capable Supported Protocols The WRT VoIP Telephone with Keypad supports SIP Session Initiation...

Page 4: ...ral Signal signaling fedsig com Figure 1 illustrates how the FT100C V VoIP Telephone can be installed as part of a VoIP phone system Figure 1 Typical VoIP Installation Figure 2 Features Figure 3 Dimen...

Page 5: ...xternal power is required install an auxiliary power supply To maintain Ingress Protection NEMA ratings use appropriately rated hardware and waterproofing techniques Choose a wall location that is fre...

Page 6: ...on the RJ45 connector indicate network connection and activity 10 Replace the faceplate 11 Set up and configure the telephone if changes are required to the default settings 12 Call to and from anoth...

Page 7: ...rol a ringer strobe light door lock or any other apparatus The on board relay is protected by a 1 A non replaceable fuse Power switched by the relay should not exceed 0 5 A at 30 Vdc The PCBA is not d...

Page 8: ...ce J5 Handset Reed Switch Interface J6 Speaker Interface J7 Keypad Interface J8 RS232 Port J9 Terminal Block see Figure 5 J10 Not used J11 Handset V C Interface J12 ISP DIP Debug UART Network Connecti...

Page 9: ...twork activity Figure 7 Network Activity Reset Switch When the telephone is operational and linked to the network use the Reset Test Function Management RESET switch Figure 8 on the Telephone board to...

Page 10: ...hrough the Device Configuration Page For further instructions reference 25500857 FT VoIP Telephone Setup Guide Field Repairs Field repairs must be carried out only by qualified technicians using OEM p...

Page 11: ...ews holding the circuit board in place Carefully remove the board 3 Install the new board and reconnect the wiring 4 If the configuration had been changed from the factory default settings reprogram t...

Page 12: ...ranslations available at signaling fedsig com Traducciones adicionales disponibles en signaling fedsig com Customer Support 1 800 344 4634 1 708 534 4756 iordersup fedsig com Technical Support 1 800 7...

Reviews: