IMSS E3265
- 17 -
Maintance
Cleaning Condenser Coil
NOTICE:
Condenser coil must be cleaned a minimum of twice per month
to insure proper refrigeration performance and prevent
compressor failure. Failure to clean condenser coil will void
condenser warranty.
It is very important that the Condenser coil is cleaned twice per month to insure proper
refrigeration performance and to prevent compressor failure. Failure to clean condenser
coil will void condenser warranty. This procedure is for Self Contained models. The
remote condenser coil must also be cleaned at same intervals.
1.
Disconnect power to the unit.
2.
On IMSS60 and IMSS84 Remove the side panel with the narrow set of louvers and on
IMSS120 remove panels from both sides at the end the control panel is located. See the
illustration in the “Bottom Panel Removal” section of this manual for panel clarification.
3.
Carefully vacuum the front surface of condenser coil. Take care not to bend coil fins with
vacuum cleaner nozzle.
4.
Reinstall side panel(s).
VACUUM FRONT
SURFACE OF
CONDENSER COIL