IMSS E3265
- 16 -
Initial Start-Up
After all the checks outlined in the installation section of this manual have been
made, the case is ready to be put into service. Turn on the Power at the breaker
box and flip the Power Switch and Light Switch on unit to the on position.
At start up from a warm unit, it is recommended that the temperature control is
set at a warm setting, such as 1 on the dial. After the unit has gone through
several cycles, turn the control to a mid range setting, then to a colder setting if
necessary to maintain desired product temperature
NOTICE:
This refrigerated display case is designed to operate
in a maximum environment of 75 DEG. F and 55% relative
humidity. Exceeding these limits will cause poor case
performance and excessive sweating.
Placing Product into Case
- Do not exceed 75 pounds of weight per shelf. Heavy product should be distributed
evenly across the entire shelving area.
- Determine desired shelving location before placing product in case. Product must be
removed to readjust shelf location.
- Allow a minimum of 2” between top of product and bottom of shelf.
- Do not overhang the front or rear of shelves with product. Improper clearance in front
and rear of shelf will block the refrigerated airflow and will cause product loss.
-Do not block the slots along the front and rear air discharge slots. Covering these slots
will block the refrigerated airflow and could cause product loss.
-The display deck is removable for cleaning and can become dislodged in shipment. To
ensure proper airflow and performance of the case, make sure that the display deck is
pushed completely down.
-Allow refrigerated models to run for at least two hours before placing pre-chilled
product into unit.
NOTICE:
CASE MUST BE STOCKED WITH PRE-CHILLED PRODUCT
ONLY.
NOTICE:
This refrigerated display case is designed to operate
in a maximum environment of 75 DEG. F and 55% relative
humidity. Exceeding these limits will cause poor case
performance and sweating of glass panels.