Fedders A3X05F2E User Manual Download Page 4

Room Air Conditioner

3

Foam Seal

Lower
Window Sash

5/8” Wood Screws

Wood Sill

Filler Panel Tab

4

Nails / Screws

L-Bracket

5

8. Cut foam seal to width of window and install between

upper and lower window sash (Fig. 4).

Caution: Do not drill a hole in bottom pan. Unit is designed
to operate with approximately 1/2” of water in bottom pan. 

Installation in window 19” to 22” wide

(Do not attach filler panels for this application)

1. Refer to steps 1 and 2 of preceding instructions. 

2. Close window until it touches behind top bar (Fig. 4).

3. Fasten lower window sash to window frame using

finishing nails, wood screws, or “L” brackets (Fig. 5).

4. If filler is required on sides of air conditioner, cut foam

seal to size and fill both sides.

5. Cut foam seal to width of window and install between

upper and lower window sash (Fig. 4).

3. To overcome storm window interference, securely attach

2” wide wood strips to the window stool and sill, with
screws. Strips should be as long as window opening and
flush with back side of stool. Thickness of strips should be
controlled by amount of interference (Fig. 3).

4. Keeping a firm grip on air conditioner, carefully center air

conditioner in window opening with the bottom bar
between the window stool and the angle bracket. Air
conditioner should slant slightly downward on the
outside as shown by half a bubble off on a carpenters
level. This outward pitch prevents water from entering
the room (Fig. 3).

5. Close the window until it touches behind air conditioner

top bar. Slide filler panels outward until they touch
window sash tracks. (Do not release grip on air
conditioner until lower window sash is in final position)
(Fig. 3).

Bracket

Upper 
Window Sash

Wood Strips
(optional)

Lower 
Window Sash

Top bar

Bottom
bar

Level

3

6. Secure top of filler panels by driving 5/8” long wood

screws into window sash through mounting holes in top
slides.

7. Secure bottom of filler panels by driving 5/8” long screws

into window sill through filler panel tabs.

Summary of Contents for A3X05F2E

Page 1: ...trouve sur le c t de la grille d corative avant pr s du tableau de commande Communiquer ces num ros lors de toute correspondance ou appel au service apr s vente ayant trait au climatiseur ENGLISH Imp...

Page 2: ...ult is an unintentional electrical discharge that occurs when electrical products or wires are damaged aged or improperly used An arc fault can be potentially hazardous if left undetected Electrical S...

Page 3: ...ose to the air conditioner as possible so that the curtain locks into place Gently pull the frame out until it is the correct length for your application 1 Tabbed side of curtain Curtain track Filler...

Page 4: ...trips to the window stool and sill with screws Strips should be as long as window opening and flush with back side of stool Thickness of strips should be controlled by amount of interference Fig 3 4 K...

Page 5: ...Turn master control to HI COOL 3 If room becomes too cool for comfort turn thermostat counter clockwise until compressor turns off air circulating fan will remain in operation 4 When desired comfort...

Page 6: ...ll result in poor air circulation DO NOT operate without filter This can render the unit inoperable Cleaning the Air Filter Every two weeks Clean the Filter 1 Turn power to OFF 2 Remove the air filter...

Page 7: ...section behind decorative front Air conditioner cooling Dirty air filter air restricted Clean air filter but room too warm Refer to Cleaning Air Filter section NO ice forming on cooling coil Thermost...

Page 8: ...IES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE IN NO EVENT S...

Page 9: ...azar el cord n llame a un t cnico de servicio autorizado El dispositivo de detecci n de arco el ctrico no es un interruptor de falla de conexi n a tierra y no se debe usar como tal El dispositivo de d...

Page 10: ...asta que la cortina est pareja arriba y abajo Fig 1 2 Deslice el marco del panel de relleno en el gabinete del acondicionador de aire usando las gu as que se encuentran arriba y abajo de la unidad Des...

Page 11: ...entanas asegure firmemente con clavos o tornillos tiras de madera de 5 1cm 2 pulg de ancho al antepecho y a la repisa de la ventana Las tiras deben tener el largo de la abertura de la ventana y deben...

Page 12: ...nto 1 Mueva el termostato hasta la posici n de mayor fr o 2 Mueva el control principal hasta HI COOL 3 Si la habitaci n alcanza una temperatura confortable gire el termostato en sentido antihorario ha...

Page 13: ...iveles de operaci n Retire los tornillo de ambos lados del gabinete Filtro de aire Frente decorativo 8 7 Para retirar el frente decorativo 1 Apague la unidad y desench fela 2 Retire los tornillos que...

Page 14: ...entilador al golpear el sistema de extracci n de agua y humedad Vibraci n de la ventana instalaci n deficiente Instalaci n incorrecta El acondicionador de aire esta extrayendo gran cantidad de humedad...

Page 15: ...USO O PROPOSITO ESPECIFICO SE LIMITAN EN DURACION A UN A O DESDE LA FECHA DE COMPRA ORIGINAL BAJO NINGUNA CIRCUMSTANCIA FEDDERS APPLIANCES SERA RESPONSABLE POR DA OS INDIRECTOS INCIDENTALES O CONSECU...

Page 16: ...her l appareil uniquement sur une prise de courant lectrique reli e la terre Ne pas utiliser avec cet appareil un c ble de rallonge ou un adaptateur de fiche Ne pas faire fonctionner cet appareil lors...

Page 17: ...po 55 9 cm 22 po de large les panneaux de remplissage sont inutiles Toutes les fen tres doivent avoir une ouverture verticale minimale de 32 4 cm 12 3 4 po Installer le climatiseur sur une fen tre o...

Page 18: ...ettes de bois de 5 1cm 2 po de large au bord int rieur et au rebord de la fen tre en utilisant des clous ou des vis Les baguettes devraient tre de la longueur de l ouverture de la fen tre et au m me n...

Page 19: ...commande principale sur HI 3 Si la temp rature de la pi ce devient inconfortable tourner le thermostat dans le sens inverse des aiguilles d une montre jusqu ce que le compresseur s arr te le ventilate...

Page 20: ...lation NE PAS faire fonctionner l appareil sans le filtre sous risque d endommager l appareil D pose du panneau frontal d coratif 1 Mettre l appareil l arr t et le d brancher 2 Retirer les vis de chaq...

Page 21: ...e temp rature trop lev e Son d la circulation de l air Son du ventilateur heurtant le syst me d vacuation de l humidit Vibration de la fen tre installation m diocre Installation incorrecte Extraction...

Page 22: ...RANTIES IMPLICITES CECI INCLUANT SANS LIMITATION LES GARANTIES IMPLICITES DE QUALIT MARCHANDE OU D APTITUDE DU PRODUIT POUR UNE APPLICATION PARTICULI RE SONT LIMIT ES DANS LE TEMPS UNE ANN E COMPTER D...

Page 23: ......

Page 24: ...ixer les panneau de remplissage Mark window sill Center 6 Marque el alf izar de la ventana Centro 222 mm Marquage de l appui de fen tre Centrer 222 mm Attach brackets Sujete el soporte Fixer l querre...