Fedders A3X05F2E User Manual Download Page 2

Room Air Conditioner

1

WARNING

Do not

remove or modify this plug

Do not

use as an on/off switch

Do not

use outdoors

Do not

push furniture against or place furniture on the

electrical cord. This can trip the test switch and/or damage
the cord and become a potential condition for arcing

Do not

attempt to repair the cord. If the cord requires

replacement, call an authorized servicer.

• The Arc Detection Device is not a Ground Fault

Interrupter and should not be used as such

• The Arc Detection Device contains an electronic circuit

board and should not be submerged or exposed to water
spray

Resetting

If the Arc Detection Device has tripped, the reset button
will pop up. 
Follow these steps to reset the Arc Detection Device:
1.  Unplug unit from electrical outlet
2.  Press the reset button
3.  Plug the unit back into electrical outlet
4.  Check to see if power has returned to the  unit

Testing

You should test the Arc Detection Device equipped power
cord monthly, after every major electrical storm, or if power
to your Room Air Conditioner has been interrupted. 
Follow these steps to test the Arc Detection Device:
1.  Unplug unit from electrical outlet
2.  Press the reset button
3.  Plug the unit back into electrical outlet
4.  Press test button. 

Unit should trip and reset button will pop up.

5.  Press reset button again for use

If above test fails, stop using the air conditioner and
contact customer service by calling the following toll-
free number: 
1-800-332-6658
or email: [email protected]

WARNING

WARNING

Power Cord with Arc Detection Device

The power cord supplied with this air conditioner is
equipped with an Arc Detection Device designed to shut
off power to the unit when it senses an arc fault condition.
An arc fault is an unintentional electrical discharge that
occurs when electrical products or wires are damaged,
aged, or improperly used. An arc fault can be potentially
hazardous if left undetected.

Electrical Shock Hazard

Plug unit only into a grounded electrical
outlet.

Do not use an extension cord or plug adapter with this
unit.

Do not operate unit with decorative front or filter
removed. 

Failure to follow these precautions could result in
electrical shock, fire or personal injury.

If the air conditioner has a serial plate rating of 115 volts
and greater than 7.5 amps, it must have its own fuse or
circuit breaker, and no other device or unit should be
operated on that fuse or circuit breaker. 

If the air conditioner has a serial plate rating of 230
volts, it must have its own fuse or circuit breaker, and no
other device or unit should be operated on that fuse or
circuit breaker.

We recommend that a qualified electrician install unit in
accordance with the National Electrical Code and local
codes and ordinances.

Use copper conductors of correct wire gauge and
protector size only.

Do not alter cord or plug end. Do not remove warning
label on cord.

Important Grounding Requirements

Air conditioner has a three-prong grounding plug on the
power supply cord, which must be plugged into a
properly grounded three-prong wall receptacle for your
protection against possible shock hazard. For models up
to and including 7.5 amperes, use a grounding type wall
receptacle to match the cord plug.

For models above 7.5 amperes use a single outlet
grounding type wall receptacle to match the cord plug.

Do not operate this air conditioner without proper time
delay circuit protection (circuit breaker or fuse). Refer to
serial plate for proper power supply requirements.

Recommended Wire Sizes

(As installed per building code) :
PROTECTOR SIZEWIRE
GAUGE
15 AMP #14 MINIMUM
20 AMP #12 MINIMUM
30 AMP #10 MINIMUM

250V

30A

250V

15A

125V

15A  

250V  

20A

Summary of Contents for A3X05F2E

Page 1: ...trouve sur le c t de la grille d corative avant pr s du tableau de commande Communiquer ces num ros lors de toute correspondance ou appel au service apr s vente ayant trait au climatiseur ENGLISH Imp...

Page 2: ...ult is an unintentional electrical discharge that occurs when electrical products or wires are damaged aged or improperly used An arc fault can be potentially hazardous if left undetected Electrical S...

Page 3: ...ose to the air conditioner as possible so that the curtain locks into place Gently pull the frame out until it is the correct length for your application 1 Tabbed side of curtain Curtain track Filler...

Page 4: ...trips to the window stool and sill with screws Strips should be as long as window opening and flush with back side of stool Thickness of strips should be controlled by amount of interference Fig 3 4 K...

Page 5: ...Turn master control to HI COOL 3 If room becomes too cool for comfort turn thermostat counter clockwise until compressor turns off air circulating fan will remain in operation 4 When desired comfort...

Page 6: ...ll result in poor air circulation DO NOT operate without filter This can render the unit inoperable Cleaning the Air Filter Every two weeks Clean the Filter 1 Turn power to OFF 2 Remove the air filter...

Page 7: ...section behind decorative front Air conditioner cooling Dirty air filter air restricted Clean air filter but room too warm Refer to Cleaning Air Filter section NO ice forming on cooling coil Thermost...

Page 8: ...IES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE IN NO EVENT S...

Page 9: ...azar el cord n llame a un t cnico de servicio autorizado El dispositivo de detecci n de arco el ctrico no es un interruptor de falla de conexi n a tierra y no se debe usar como tal El dispositivo de d...

Page 10: ...asta que la cortina est pareja arriba y abajo Fig 1 2 Deslice el marco del panel de relleno en el gabinete del acondicionador de aire usando las gu as que se encuentran arriba y abajo de la unidad Des...

Page 11: ...entanas asegure firmemente con clavos o tornillos tiras de madera de 5 1cm 2 pulg de ancho al antepecho y a la repisa de la ventana Las tiras deben tener el largo de la abertura de la ventana y deben...

Page 12: ...nto 1 Mueva el termostato hasta la posici n de mayor fr o 2 Mueva el control principal hasta HI COOL 3 Si la habitaci n alcanza una temperatura confortable gire el termostato en sentido antihorario ha...

Page 13: ...iveles de operaci n Retire los tornillo de ambos lados del gabinete Filtro de aire Frente decorativo 8 7 Para retirar el frente decorativo 1 Apague la unidad y desench fela 2 Retire los tornillos que...

Page 14: ...entilador al golpear el sistema de extracci n de agua y humedad Vibraci n de la ventana instalaci n deficiente Instalaci n incorrecta El acondicionador de aire esta extrayendo gran cantidad de humedad...

Page 15: ...USO O PROPOSITO ESPECIFICO SE LIMITAN EN DURACION A UN A O DESDE LA FECHA DE COMPRA ORIGINAL BAJO NINGUNA CIRCUMSTANCIA FEDDERS APPLIANCES SERA RESPONSABLE POR DA OS INDIRECTOS INCIDENTALES O CONSECU...

Page 16: ...her l appareil uniquement sur une prise de courant lectrique reli e la terre Ne pas utiliser avec cet appareil un c ble de rallonge ou un adaptateur de fiche Ne pas faire fonctionner cet appareil lors...

Page 17: ...po 55 9 cm 22 po de large les panneaux de remplissage sont inutiles Toutes les fen tres doivent avoir une ouverture verticale minimale de 32 4 cm 12 3 4 po Installer le climatiseur sur une fen tre o...

Page 18: ...ettes de bois de 5 1cm 2 po de large au bord int rieur et au rebord de la fen tre en utilisant des clous ou des vis Les baguettes devraient tre de la longueur de l ouverture de la fen tre et au m me n...

Page 19: ...commande principale sur HI 3 Si la temp rature de la pi ce devient inconfortable tourner le thermostat dans le sens inverse des aiguilles d une montre jusqu ce que le compresseur s arr te le ventilate...

Page 20: ...lation NE PAS faire fonctionner l appareil sans le filtre sous risque d endommager l appareil D pose du panneau frontal d coratif 1 Mettre l appareil l arr t et le d brancher 2 Retirer les vis de chaq...

Page 21: ...e temp rature trop lev e Son d la circulation de l air Son du ventilateur heurtant le syst me d vacuation de l humidit Vibration de la fen tre installation m diocre Installation incorrecte Extraction...

Page 22: ...RANTIES IMPLICITES CECI INCLUANT SANS LIMITATION LES GARANTIES IMPLICITES DE QUALIT MARCHANDE OU D APTITUDE DU PRODUIT POUR UNE APPLICATION PARTICULI RE SONT LIMIT ES DANS LE TEMPS UNE ANN E COMPTER D...

Page 23: ......

Page 24: ...ixer les panneau de remplissage Mark window sill Center 6 Marque el alf izar de la ventana Centro 222 mm Marquage de l appui de fen tre Centrer 222 mm Attach brackets Sujete el soporte Fixer l querre...

Reviews: