Fedders A3X05F2E User Manual Download Page 3

Room Air Conditioner

2

Tools Needed

Screwdrivers

Tape
Measure

Carpenter’s Level

5/8” wood screws..............9

Brackets ............................2

A

B

A

B

Installation Parts Kit 

Window Requirements

Air conditioner is factory prepared for installation in
standard double hung windows (air conditioner cannot be
installed in other types of windows). The air conditioner
can be installed in windows 23” to 34” wide when filler
panels are used. In windows 19” to 22” wide the air
conditioner can be installed without the filler panels. All
windows must open at least 12 3/4” vertically.

Install the air conditioner in a window where there will be
enough clearance around the cabinet to allow ample
circulation of air through unit. All supporting parts should
be secured to firm wood, masonry, or metal.

Installation in window 23” to 34” wide

1. Open and mark center line of window. Measure and mark

6” to the right of the center line and 6” to the left of the
center line (Fig. 2).

2. Place bracket so that the inside edge rests on the

appropriate 6” mark. Secure brackets with two (2) 1” long
wood screws (Fig. 2).

Filler Panel Installation

1. Place tabbed side of curtain in track on side of air

conditioner cabinet, and slide down the track until the
curtain is even top and bottom (Fig.1).

2. Slide the filler panel frame onto the air conditioner

cabinet using the tracks on the top and bottom of the
unit. Slide the frame as close to the air conditioner as
possible so that the curtain locks into place. Gently pull
the frame out until it is the correct length for your
application.

1

Tabbed side
of curtain

Curtain
track 

Filler panel frame

Curtain

Filler panel 
frame track (top bar)

Filler panel 
frame track
(bottom bar)

6"

6"

Center 
of
window
opening

5/8” Screws

Bracket

Bracket

Window Sill

5/8” Screws

2

Additional Safety Precautions 

Do not

cut, alter or remove any of the expanded

polystyrene (styrofoam) inside this air conditioner.

Do not

store or use gasoline or other flammable vapors

and liquids in the vicinity of this or any other appliance.
The fumes can create a fire hazard or explosion.

Do not

introduce objects in the air discharge area. This

could cause permanent damage.

Do not

pour liquids on the air conditioner as this could

cause a malfunction. With the unit unplugged, use a
damp cloth for cleaning the unit.

Do not

use strong solvents to clean the air conditioner. 

Clean the air conditioner filter every two weeks to avoid
overheating caused by air obstruction. Do not operate
without filter.

Do not

obstruct the air intake area of your air

conditioner, as this could cause overheating, thus
activating the unit’s security switch and shutting off the
unit.

Do not

block air circulation to outside louvers of cabinet.

Do not

block air flow inside with blinds, curtains, or

furniture, or outside with shrubs, enclosures, or other
buildings.

Do not

run the air conditioner with an outside

protective cover in place. This could result in fire or
mechanical damage within the air conditioner.

Summary of Contents for A3X05F2E

Page 1: ...trouve sur le c t de la grille d corative avant pr s du tableau de commande Communiquer ces num ros lors de toute correspondance ou appel au service apr s vente ayant trait au climatiseur ENGLISH Imp...

Page 2: ...ult is an unintentional electrical discharge that occurs when electrical products or wires are damaged aged or improperly used An arc fault can be potentially hazardous if left undetected Electrical S...

Page 3: ...ose to the air conditioner as possible so that the curtain locks into place Gently pull the frame out until it is the correct length for your application 1 Tabbed side of curtain Curtain track Filler...

Page 4: ...trips to the window stool and sill with screws Strips should be as long as window opening and flush with back side of stool Thickness of strips should be controlled by amount of interference Fig 3 4 K...

Page 5: ...Turn master control to HI COOL 3 If room becomes too cool for comfort turn thermostat counter clockwise until compressor turns off air circulating fan will remain in operation 4 When desired comfort...

Page 6: ...ll result in poor air circulation DO NOT operate without filter This can render the unit inoperable Cleaning the Air Filter Every two weeks Clean the Filter 1 Turn power to OFF 2 Remove the air filter...

Page 7: ...section behind decorative front Air conditioner cooling Dirty air filter air restricted Clean air filter but room too warm Refer to Cleaning Air Filter section NO ice forming on cooling coil Thermost...

Page 8: ...IES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE IN NO EVENT S...

Page 9: ...azar el cord n llame a un t cnico de servicio autorizado El dispositivo de detecci n de arco el ctrico no es un interruptor de falla de conexi n a tierra y no se debe usar como tal El dispositivo de d...

Page 10: ...asta que la cortina est pareja arriba y abajo Fig 1 2 Deslice el marco del panel de relleno en el gabinete del acondicionador de aire usando las gu as que se encuentran arriba y abajo de la unidad Des...

Page 11: ...entanas asegure firmemente con clavos o tornillos tiras de madera de 5 1cm 2 pulg de ancho al antepecho y a la repisa de la ventana Las tiras deben tener el largo de la abertura de la ventana y deben...

Page 12: ...nto 1 Mueva el termostato hasta la posici n de mayor fr o 2 Mueva el control principal hasta HI COOL 3 Si la habitaci n alcanza una temperatura confortable gire el termostato en sentido antihorario ha...

Page 13: ...iveles de operaci n Retire los tornillo de ambos lados del gabinete Filtro de aire Frente decorativo 8 7 Para retirar el frente decorativo 1 Apague la unidad y desench fela 2 Retire los tornillos que...

Page 14: ...entilador al golpear el sistema de extracci n de agua y humedad Vibraci n de la ventana instalaci n deficiente Instalaci n incorrecta El acondicionador de aire esta extrayendo gran cantidad de humedad...

Page 15: ...USO O PROPOSITO ESPECIFICO SE LIMITAN EN DURACION A UN A O DESDE LA FECHA DE COMPRA ORIGINAL BAJO NINGUNA CIRCUMSTANCIA FEDDERS APPLIANCES SERA RESPONSABLE POR DA OS INDIRECTOS INCIDENTALES O CONSECU...

Page 16: ...her l appareil uniquement sur une prise de courant lectrique reli e la terre Ne pas utiliser avec cet appareil un c ble de rallonge ou un adaptateur de fiche Ne pas faire fonctionner cet appareil lors...

Page 17: ...po 55 9 cm 22 po de large les panneaux de remplissage sont inutiles Toutes les fen tres doivent avoir une ouverture verticale minimale de 32 4 cm 12 3 4 po Installer le climatiseur sur une fen tre o...

Page 18: ...ettes de bois de 5 1cm 2 po de large au bord int rieur et au rebord de la fen tre en utilisant des clous ou des vis Les baguettes devraient tre de la longueur de l ouverture de la fen tre et au m me n...

Page 19: ...commande principale sur HI 3 Si la temp rature de la pi ce devient inconfortable tourner le thermostat dans le sens inverse des aiguilles d une montre jusqu ce que le compresseur s arr te le ventilate...

Page 20: ...lation NE PAS faire fonctionner l appareil sans le filtre sous risque d endommager l appareil D pose du panneau frontal d coratif 1 Mettre l appareil l arr t et le d brancher 2 Retirer les vis de chaq...

Page 21: ...e temp rature trop lev e Son d la circulation de l air Son du ventilateur heurtant le syst me d vacuation de l humidit Vibration de la fen tre installation m diocre Installation incorrecte Extraction...

Page 22: ...RANTIES IMPLICITES CECI INCLUANT SANS LIMITATION LES GARANTIES IMPLICITES DE QUALIT MARCHANDE OU D APTITUDE DU PRODUIT POUR UNE APPLICATION PARTICULI RE SONT LIMIT ES DANS LE TEMPS UNE ANN E COMPTER D...

Page 23: ......

Page 24: ...ixer les panneau de remplissage Mark window sill Center 6 Marque el alf izar de la ventana Centro 222 mm Marquage de l appui de fen tre Centrer 222 mm Attach brackets Sujete el soporte Fixer l querre...

Reviews: