ach measurement takes around 60 seconds, and 

each memory checking takes about 1 second 

Protection against electric 
shock 

Type BF 

 

Cuff 

IP classification 

IP21 

Working Environment 

Temperature: 10~40°C 
Humidity: 

85%

RH 

Pressure: 86~106 kPa 

Transport and storage 
  Environment   

Temperature: -20~60°C 
Humidity:

   

85% 

RH 

Pressure: 86~106 kPa 

Electric Shock Protection 

Internal power unit 

Memory Capacity 

2 Memory sets ; each 90 reading of data including 
date and time 

Inflation 

Automatic Inflation by internal pump 

Deflation 

Automatic speed deflation system controlled by 
internal electromagnetic valve. 

Display 

LCD digital display ; It can show Pressure, Pulse, 
Date, Time 

Color Backlight display on 
LCD (Optional) 

White backlight display when power on 
Green backlight display when result is normal 
Red backlight display when result is abnormal 

Switch 

3(ON/OFF, Memory, SET) 

Life Time 

Machine : 5 years or 10000 times 
Cuff : 10000 times 
AC Adapter: 50000 hours 

Contents 

-Cuff   
-4 x1.5V AA alkaline batteries 6V (Optional) 
-Carrying bag(Optional) 
-Instruction Manual 

Note: 

These specification may be changed without prior notice. 

 

 

 

Contraindications: 

1.  Heart disease 

2.  High blood pressure or other circulatory disease 

3.  Arm injury 

 

 

Patient Populations: 

The device is intended to use for adults. DO NOT use this device on infants or small 

children.. 

Summary of Contents for FT-C21Y

Page 1: ...the manual appropriately for future reference This User Manual is suitable to the following models FT C21Y FT C22Y FT C23Y FT C24Y FTC11B FT C12B FT C21Y V FT C22Y V FTC23Y V FT C24Y V FT C11B V FT C...

Page 2: ...ual by using a non invasive technique in which an inflatable cuff is wrapped around the arm The cuff circumference is limited to 8 7 inches to 12 6 inches Specification Product Name Arm Automatic Bloo...

Page 3: ...by internal electromagnetic valve Display LCD digital display It can show Pressure Pulse Date Time Color Backlight display on LCD Optional White backlight display when power on Green backlight display...

Page 4: ...o protect natural environment by respecting national and or local recycling regulations when disposing of the battery and the product at the end of their useful live II PRECAUTION FOR USE AND MAINTENA...

Page 5: ...DO NOT wrap the cuff on the arm on the side of a mastectomy 13 DO NOT use the device in the vicinity of flammable gases such as those used for anesthesia Doing so could ignite the gases and cause an e...

Page 6: ...DO NOT attempt to disassemble the device User can open battery cover for new battery installation DO NOT bend the cuff or air hose excessively 5 NEVER clean the blood pressure monitor with thinners or...

Page 7: ...n Deflation Indicator 8 Blood Pressure Measurement Unit 9 Battery Symbol 10 Irregular heartbeat Indicator 11 Memory Record Number Back light display function is optional IV Measure Procedure Battery L...

Page 8: ...ced Figure 3 Figure 4 NOTE AC adapter is optional for power supply Only use the adapter provided by manufacturer that is complying with EC60601 1 standard requirements Do not touch the AC adapter with...

Page 9: ...or Kpa and the mmHg is the definition unit When the machine is turned off press the button ON OFF more than about 10 seconds till LCD blinks then press Memory button to switch between mmHg and Kpa Arm...

Page 10: ...S CUFF PRESSURE MAY EFFECT BLOOD FLOW AND CAUSE HARMFUL INJURY Figure 6 Note The cuff is TYPE BF APPLIED PART Measuring Process POSTURE FOR TAKING BLOOD PRESSURE MONITOR Cuff should be at the same hei...

Page 11: ...will speak out the displayed blood pressure heart rate If an irregular heartbeat is detected the IRREGULAR HEARTBEAT symbol will appear and blink in the display screen See Figure9 NOTE Do not self di...

Page 12: ...This model has 2 Person memory banks and 90 memories storage for each Press and release SET button can prompt to P1 Person 1 or P2 Person 2 as your ID to access the measurement for the first time oper...

Page 13: ...85 89 Stage 1 Hypertension 140 159 90 99 YELLOW Stage 2 Hypertension 160 179 100 109 ORANGE Stage 3 Hypertension 180 110 RED Note The graph is not exact but may be used as a guide in understanding non...

Page 14: ...each measurement finish The device will speak out the last time displayed memory blood pressure systolic and diastolic pressure and heart rate when reading memory result Note The voice function is ONL...

Page 15: ...tion method After testing the result displayed on LCD including systolic pressure diastolic pressure and pulse will be automatically sent to the blue tooth receiving device such as mobile phone The ad...

Page 16: ...during the day and will also be affected by emotional and physical condition LCD shows Er U Insufficient inflation Measure again LCD shows Er H Inflation over 305 mmHg Measure again LCD shows Er 1 Un...

Page 17: ...eception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receivi...

Page 18: ...ns power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1 kV differential mode 2 kV common mode Not applicable Mains power quality should be that of a typic...

Page 19: ...urvey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol Radiated RF IEC 61000 4 3 3 V m 80 MHz t...

Page 20: ...117 0 117 0 233 0 1 0 369 0 369 0 738 1 1 167 1 167 2 333 10 3 689 3 689 7 379 100 11 667 11 667 23 333 For transmitters rated at a maximum output power not listed above the recommended separation di...

Page 21: ...PART Symbol for Follow operating instructions IP21 Symbol for the IP classification Symbol for RF transmitters Manufacturer FUDAKANG INDUSTRIAL CO LTD Address No 8 Yinghe Road Yuanjiangyuan Managemen...

Reviews: