![Fcar F4SN HD Pad Pro Manual Download Page 33](http://html.mh-extra.com/html/fcar/f4sn-hd-pad-pro/f4sn-hd-pad-pro_manual_547282033.webp)
FCAR F4SN Manual
33
in the pop-up window (the file name is best named after the vehicle information
for review), select [OK] to return;
3)
Click [OK] to start recording, manually slide the touch screen slowly to the last
data column; click the [Stop] button in the lower left corner to stop recording
and automatically save the live data;
4)
The live data is recorded and the system automatically saves it (Hint: the live
data can be recorded for up to 2 minutes). [Data Review] in the data
management function to view the saved data stream.
➢
How to perform live data comparison
1)
Click the [Select] function icon“
”
, In the pop-up window, select the
parameter item that needs to be compared with the data, and select [OK] to
return;
2)
Click the [Live Data Comparison] function icon“
”
,
in any hidden column
on the right. In the pop-up dialog box, select the data file of the same model
saved, and select [OK] to return;
3)
At this point, the live data interface has a column “comparison value”, as shown
in Figure 3.5-5, the service technician can quickly find and eliminate the vehicle
fault problem through system parameter comparison.