![Fayat Group DYNAPAC DRP70D Operating Instruction Download Page 96](http://html1.mh-extra.com/html/fayat-group/dynapac-drp70d/dynapac-drp70d_operating-instruction_3715383096.webp)
2.
Turn the outer V-belt pulley with the suitable tool, until the
required belt tension is achieved.
Counter the inner V-belt pulley with a suitable
tool.
3.
Retighten the threaded pins, tightening torque: 10 Nm
(7.4 ft
·
lbf).
1.
Fasten the V-belt guard (1).
8.11.4
Checking the oil level in the exciter housing
NOTICE!
Components may get damaged!
–
Use only oil of the permitted specification
Chapter 8.4 „List of fuels and lubri-
.
–
Do not use low-ash engine oils for the exciter
shaft housing.
Protective equipment:
n
Working clothes
n
Safety shoes
n
Protective gloves
1.
Park the machine on level ground.
2.
Park the machine safely
Chapter 6.4 „Parking the machine
in secured condition“ on page 57
.
3.
Allow the machine to cool down.
Fig. 109
Concluding work
Fig. 110
Maintenance – As required
DRP70D
96
Summary of Contents for DYNAPAC DRP70D
Page 2: ...2...
Page 6: ...Table of contents DRP70D 6...
Page 7: ...1 Introduction Introduction DRP70D 7...
Page 11: ...2 Technical data Technical data DRP70D 11...
Page 15: ...3 Concerning your safety Concerning your safety DRP70D 15...
Page 40: ...Concerning your safety Signage DRP70D 40...
Page 41: ...4 Indicators and control elements Indicators and control elements DRP70D 41...
Page 45: ...5 Checks prior to start up Checks prior to start up DRP70D 45...
Page 51: ...6 Operation Operation DRP70D 51...
Page 58: ...Operation Parking the machine in secured condition DRP70D 58...
Page 59: ...7 Loading transporting the machine Loading transporting the machine DRP70D 59...
Page 62: ...Loading transporting the machine Lashing the machine to the transport vehicle DRP70D 62...
Page 63: ...8 Maintenance Maintenance DRP70D 63...
Page 99: ...9 Troubleshooting Troubleshooting DRP70D 99...
Page 109: ...10 Disposal Disposal DRP70D 109...
Page 111: ......
Page 112: ......