6.10 Maintenance every 2 years
6.10.1
Change hydraulic oil and filter
WARNING!
Danger of scalding!
Danger of scalding by hot oil.
NOTICE!
Park the machine on level ground.
Drain off hydraulic oil at operating temperature.
Replace the hydraulic oil filter with every hydraulic
oil change.
Change the hydraulic oil at least every 2 years.
For quality and quantity of oil refer to the "table of
fuels and lubricants".
ENVIRONMENT!
Catch running out oil and dispose of environmen-
tally together with the filter.
Open the hood.
Clean hydraulic tank and surrounding area.
Take out the breather filter (3).
Replace and insert the breather filter with seal ring (2).
Replace the plug and screw it in tightly.
Changing the breather filter
Fig. 69
Maintenance – Maintenance every 2 years
BPR 70/70 D
71