523323 PUBLICATION DATE 2 OCT 2006.DOC
INSTALLATION AND MAINTENANCE MANUAL
19
6. TROUBLE SHOOTING AIDS
6.1. EMERGENCY DOOR OPENING
Whenever the door fails to open, e.g. in case of a current failure or in emergency situation, we recommend
you to proceed as follows:
•
Before the door is open, check the washing water temperature and machine parts temperature.
IF THESE PARTS ARE TOO HOT, DO NOT OPEN ! DANGER OF INJURY !
•
After cooling down, remove the lower service panel by loosening the screws. Behind this service panel, at the
left side of the machine you will find a string for emergency door opening.
•
While pulling this string downwards, you will unblock the door lock.
•
You can open the door.
•
Install the service panel.
6.2. FILLING TIME TOO LONG
LOW WATER PRESSURE:
More machines are filling up in the same time.
Filter of inlet valve is blocked (clogged):
Stop the main water supply, remove filters from inlet valves, clean up the filters and put them back.
THE HOSE IS LEAKING:
Replace the broken hose or seal on connection.
Defected inlet valve:
Replace the inlet valve.
6.3. HEATING TIME TOO LONG
SEDIMENT OR DEFECT ON THE ELECTRICAL HEATING ELEMENTS:
Replace the heating elements.
6.4. DRAIN TIME TOO LONG
DRAIN PIPE SYSTEM IS CLOGGED :
Clean it up.
NON-FUNCTIONAL DRAIN VALVE:
Clean or replace the drain valve.
6.5. PROGRAMMER PROBLEMS
See the chapter „Troubleshooting“ in the programming manual according to your machine type:
•
„Programming manual - Electronic timer“