18
INSTALLATION AND MAINTENANCE MANUAL
523323 PUBLICATION DATE 2 OCT 2006.DOC
•
Turning the drum pulley (1) slowly and by the belt (2) offset from its working position at the same time, you will
reach tension reduction and you can remove the pulley.
•
Put the new belt of the same type on the motor pulley (4) first and then partly on the drum pulley (1), so that the
tension spring (6) is hooked. Turning the drum pulley (1) slowly put on the belt.
•
The motor pulley and the drum pulley must be in one level.
•
Testing force of the correctly tight belt between the drum pulley and the motor pulley measured by tension
meter for measuring the force in the belt is 180-250N for machines 18 kg / 40 lb, 22 kg / 50 lb.
5.9. FUSES
FUSE VALUES
You can find values of fuses on electrical scheme delivered with the machine or on the machine label.
See also chapters 3.1. and 3.2.