Fault

When the lance is turned on pressure 

values decrease and increase

Cause 

•  The nozzle is either clogged or deformed.

•  Either boiler coil or lance are clogged with 

limestone.

Repair 

•  Either clean it or replace it.

•  Descaling.

Fault

To much vibrations at the delivery

Cause 

•  The pressure tank is run down.

•  The valve are worn out or dirty.

Repair

•  Check the pressure in the tank.

•  Check and/or replace.

Fault

The pump does not  reach the fixed pressures

Cause 

•  The pump sucks air.

•  The valves are worn out.

•  The setting valve area is worn out.

•  The nozzle is unsuitable or worn out.

•  The seals are worn out.

Repair 

•  Check the suction pipes.

•  Check and/or replace.

•  Contact an authorised service centre.

•  Contact an authorised service centre.

Fault

Irregular pressure fluctuations

Cause 

•  The suction and/or delivery valves are worn 

out.

•  Presence of foreign matters  in the valves, 

which generate bad functioning.

•  Air suction.

•  The seals are worn out.

Re-

pair 

•  Check and/or replace.

•  Check and clean the replace.

•  Check the suction pipe.

•  Check and/or replace  the seals.

Fault

Pressure leakage

Cause 

•  The nozzle is worn out.

•  The suction and/or delivery valves are 

broken or down.

•  Presence of foreign matters  in the valves, 

which generate  the valves bad functioning.

•  The setting valve area is worn out.

•  The seals are worn out.

Repair 

•  Replace the nozzle.

•  Check and/or replace the valves.

•  Check and clean the valves.

•  Check and/or replace the setting valve area.

•  Replace the seals.

Fault

Noisiness

Cause 

•  Air suction.

•  The suction and/or delivery valve springs 

are broken or down.

•  Foreign matters in the suction  and delivery 

valves.

•  The bearings are worn out.

•  Extreme liquid temperature.

Repair 

•  Check the suction pipes.

•  Replace the valve springs.

•  Check and clean the suction and delivery 

valves.

•  Replace the bearings.

•  Reduce the liquid temperature.

Fault

Water is in the oil

Cause 

•  The O-ring casing is worn out.

•  High moisture in the air.

•  The seals are completely worn out.

Repair

•  Check and/or replace the O-ring.

•  Replace the oil with double frequency in 

respect of the one suggested.

•  Replace the seals.

Fault

Filtrations of water from the drains 

between casing and head

Cause 

•  The seals are worn out.

•  The piston is worn out.

•  The O-ring of the piston cap is worn out.

Repair

•  Replace the seals.

•  Replace the piston.

•  Replace the seal.

Fault

Filtrations of oil from the drains be-

tween head and casing

Cause 

•  O-ring seals of casing are worn out.

Repair 

•  Replace the seals.

Fault

Turning  on  the  burner  switch  the 

boiler does not start

Cause 

•  No fuel.

•  Fuel filter is clogged.

•  Fuel pump is either blocked or burnt out.

•  Damaged thermostat.

•  Ignition spark insufficient or totally lacking.

•  The space among the electrodes is not 

correct.

•  Burn out fuse.

Repair 

•  Check the level in the tank and check 

whether the rigid suction pipe is clean.

•  Replace the line filter.

•  Replace it.

•  Replace it.

•  Contact an authorised service centre.

•  Check the positioning.

•  Replace it.

EN

24

Summary of Contents for NPX XP

Page 1: ...stru es antes da utiliza o HUOMIO lue ohjeet ennen k ytt PA NJA prije upotrebe pro itajte upute POZOR pred uporabo preberite navodila Thecnical data plate Placa dato t cnicos IDROPULITRICE AD ALTA PRE...

Page 2: ...EET GLAVNI KOMANDNI DIJELOVI GLAVNI DELI ZA UPRAVLJANJE XP LP fig A A B C In base al modello si possono verificare delle differenze nella fornitura Depending on the model there are differences in the...

Page 3: ...ER PRINCIPALES RGANOS DE CONTROL HOOFDSCHAKELAAR PRINCIPAIS RG OS DE COMANDO P OHJAUSLAITTEET GLAVNI KOMANDNI DIJELOVI GLAVNI DELI ZA UPRAVLJANJE Diesel Detergent Consoante o modelo existem diferen as...

Page 4: ...2 INSTALLAZIONE INSTALLATION MISE EN PLACE INSTALLATION INSTALACI N INSTALATIE INSTALA O ASENNUS INSTALACIJA MONTA A fig C fig B optional 1 2 inch 13 mm 5 40 C min 30 l min max 1 MPa fig D fig E fig F...

Page 5: ...umie wachlarzowy pahlja asti curek vode solfj dersformad str le mlaznica raspr iva jet evantai jet fan getto spillo ventaglio spread pattern pencil jet jet variable vario Duese chorro regulable dunnes...

Page 6: ...6 Diesel 4 5 fig L 1 2 3 6 7...

Page 7: ...A ESQUEMA H DRICO WATERSCHEMA ESQUEMA HIDR ULICO VEDENKYTKENT KAAVIO SHEMA VODENOG KRUGA VODOVODNA SHEMA H2O IG 1 M3 TS EV TR IB M2 GG L1 SCHEMAELETTRICO ELECTRICDIAGRAM SCHEMAELECTRIQUE ELEKTROSCHEMA...

Page 8: ...LKX_LP_1Ph_230V LKX_LP_3Ph_400V 8...

Page 9: ...s or chemicals may put the appliance s safety at risk 05a WARNING Do not use the machine within range of persons unless they wear protective clothing 05b Do not allow other people or animals within a...

Page 10: ...21WARNING Risk of explosion Do not spray flammable liquids 22WARNING To ensure machine safety use only original spare parts from the manufacturer or approved by the manufacturer 23WARNING Do not dire...

Page 11: ...e unit before operation Unscrew the high pressure line at the high pressure outlet of the unit Switch on the unit and let it run until water free of bubbles emerges at the high pressure outlet Switch...

Page 12: ...in order to avoid unintentional starting Any automatic start of the machine without pressing the gun trigger is attributable to air bubbles in the water or other similar phenomena which do not imply t...

Page 13: ...for the quantity required as described in the DETER GENT SUCTION section WARNING In case of operation indoors adequate ventilation and gas venting must be assured THERMOSTAT SET ABOVE 100 C USE WARNI...

Page 14: ...ditions BOILER CLEANING WARNING For all maintenance of the boiler of the high pressure pump and of the machine it is necessary to address to qualified personnel or to an authorized assistance center T...

Page 15: ...ves Check and clean the valves Check and or replace the setting valve area Replace the seals Fault Noisiness Cause Air suction The suction and or delivery valve springs are broken or down Foreign matt...

Page 16: ...not included in the warranty Parts subject to normal wear The high pressure tube and optional accessories Accidental damage caused by transport neglect or inadequate treatment incor rect or improper u...

Page 17: ...erungen sowie den Normen EN est en conformidad con las directivas CE y sus sucesivas modificaciones y tambi n con la norma EN in overeenstemming is met de Richtlijnen EG en latere wijzigingen daarop e...

Reviews: