background image

“OFF”  and  that  the  water  filter  is  fitted  into 

the pump’s inlet pipe.

•  Screw the snap connection into place by hand, 

without the aid of tools.

•  Connect  the  water  supply  hose  to  the  snap 

connection.  The  hose  must  have  an  inside 

diameter of at least 13 mm (1/2”).

•  Connect the high pressure hose to the pump’s 

outlet  pipe.  Press  the  high  pressure  hose 

coupling fully down and then screw into place 

by hand without the aid of tools.

•  Connect the high pressure hose to the gun.

•  Turn  the  water  tap  fully  on.  The  water 

temperature absolutely must be below 40°C.

IMPORTANT:

  The  washer  machine  has  to 

operate with clean water in order to avoid any 

damages to the washer machine itself.

•  Release  the  gun  safety  catch  and  keep  the 

trigger pressed, allowing the water to flow until 

all the air has been expelled.

•  Fit the lance into the gun.

•  Fit the nozzle  into the lanxce.

•  Connect the plug to the power socket.

>  1ST START-UP

When starting up for the first time or after a long pe-

riod out of use, connect the intake line only for a few 

minutes so that any dirt is vented from the delivery 

outlet 

>  START-UP

(

fig. 

H

)

•  Whenever  using  the  high-pressure  cleaner,  users  are 

urged to hold the gun in the correct position, with one 

hand on the grip and the other on the spray rod.

•  To  start  the  machine,  press  the  gun  trigger 

and at the same time turn the master switch to 

“ON”

>  TO WASH WITH HOT WATER

(fig. 

A

)

turn the burner switch and select the desired tem-

perature setting. To add detergent or disinfectant to 

the water jet, open the regulator to the setting for 

the  quantity  required  as  described  in  the  “DETER-

GENT SUCTION” section.

 WARNING:

  In  case  of  operation  indoors, 

adequate ventilation and gas venting must be 

assured.

>  THERMOSTAT SET ABOVE 100 ° C: USE WARNINGS.

When working with temperatures exceeding 100° C, 

follow these steps:

-   The  working  pressure  must  not  exceed  the 

limit of 32 bar.

-  Through  the  knob  on  the  bypass  valve  of  the 

pump, you can adjust the pressure.

-  Assemble steam nozzle 3.749.0183 (optional)

>   DETERGENT SUCTION

at low pressure 

(if included)

(see fig. 

I

)

The adjusting head allow you to select water jet at 

low and high pressure. The pressure selection is car-

ried out by rotating the adjusting head. To increase 

the  pressure,  rotate  the  adjusting  head  clockwise, 

to reduce the pressure rotate it anti-clockwise. The 

detergent suction is automatic when the adjusting 

head of the lance is rotate for low pressure operation 

(anti-clockwise).

>   DETERGENT SUCTION

at hght pressure 

(if included)

(see fig. 

I

)

When you start the machine, the mixing of the de-

tergent with the water is automatic at the water pas-

sage. The quantity of sucked detergent depends on 

the quantity set with the detergent adjusting knob.

 CAUTION: Make use only of liquid detergent, do not 

absolutely use acid or too much alkaline products.

 

We  suggest  you  to  make  use  of  our  products,  which 

have been studied for the use with  washer machines.

CARE AND MAINTENANCE

(vedi fig. 

L

)

 

IMPORTANT:  Before  doing  any  work 

on  the  cleaner,  discharge  the  pressure 

and  disconnect  the  electricity  and  water 

supplies.

CHECKING THE PUMP OIL LEVEL

Check  the  oil  level  periodically.    The  oil  must  be 

changed  for  the  first  time  after  50  working  hours, 

with  subsequent  changes  every  500  hours.    SAE 

20/30 , 15W-40, 20W-40 oil is recommended .

EN

22

Summary of Contents for NPX XP

Page 1: ...stru es antes da utiliza o HUOMIO lue ohjeet ennen k ytt PA NJA prije upotrebe pro itajte upute POZOR pred uporabo preberite navodila Thecnical data plate Placa dato t cnicos IDROPULITRICE AD ALTA PRE...

Page 2: ...EET GLAVNI KOMANDNI DIJELOVI GLAVNI DELI ZA UPRAVLJANJE XP LP fig A A B C In base al modello si possono verificare delle differenze nella fornitura Depending on the model there are differences in the...

Page 3: ...ER PRINCIPALES RGANOS DE CONTROL HOOFDSCHAKELAAR PRINCIPAIS RG OS DE COMANDO P OHJAUSLAITTEET GLAVNI KOMANDNI DIJELOVI GLAVNI DELI ZA UPRAVLJANJE Diesel Detergent Consoante o modelo existem diferen as...

Page 4: ...2 INSTALLAZIONE INSTALLATION MISE EN PLACE INSTALLATION INSTALACI N INSTALATIE INSTALA O ASENNUS INSTALACIJA MONTA A fig C fig B optional 1 2 inch 13 mm 5 40 C min 30 l min max 1 MPa fig D fig E fig F...

Page 5: ...umie wachlarzowy pahlja asti curek vode solfj dersformad str le mlaznica raspr iva jet evantai jet fan getto spillo ventaglio spread pattern pencil jet jet variable vario Duese chorro regulable dunnes...

Page 6: ...6 Diesel 4 5 fig L 1 2 3 6 7...

Page 7: ...A ESQUEMA H DRICO WATERSCHEMA ESQUEMA HIDR ULICO VEDENKYTKENT KAAVIO SHEMA VODENOG KRUGA VODOVODNA SHEMA H2O IG 1 M3 TS EV TR IB M2 GG L1 SCHEMAELETTRICO ELECTRICDIAGRAM SCHEMAELECTRIQUE ELEKTROSCHEMA...

Page 8: ...LKX_LP_1Ph_230V LKX_LP_3Ph_400V 8...

Page 9: ...s or chemicals may put the appliance s safety at risk 05a WARNING Do not use the machine within range of persons unless they wear protective clothing 05b Do not allow other people or animals within a...

Page 10: ...21WARNING Risk of explosion Do not spray flammable liquids 22WARNING To ensure machine safety use only original spare parts from the manufacturer or approved by the manufacturer 23WARNING Do not dire...

Page 11: ...e unit before operation Unscrew the high pressure line at the high pressure outlet of the unit Switch on the unit and let it run until water free of bubbles emerges at the high pressure outlet Switch...

Page 12: ...in order to avoid unintentional starting Any automatic start of the machine without pressing the gun trigger is attributable to air bubbles in the water or other similar phenomena which do not imply t...

Page 13: ...for the quantity required as described in the DETER GENT SUCTION section WARNING In case of operation indoors adequate ventilation and gas venting must be assured THERMOSTAT SET ABOVE 100 C USE WARNI...

Page 14: ...ditions BOILER CLEANING WARNING For all maintenance of the boiler of the high pressure pump and of the machine it is necessary to address to qualified personnel or to an authorized assistance center T...

Page 15: ...ves Check and clean the valves Check and or replace the setting valve area Replace the seals Fault Noisiness Cause Air suction The suction and or delivery valve springs are broken or down Foreign matt...

Page 16: ...not included in the warranty Parts subject to normal wear The high pressure tube and optional accessories Accidental damage caused by transport neglect or inadequate treatment incor rect or improper u...

Page 17: ...erungen sowie den Normen EN est en conformidad con las directivas CE y sus sucesivas modificaciones y tambi n con la norma EN in overeenstemming is met de Richtlijnen EG en latere wijzigingen daarop e...