background image

>   DESCRIPTION OF THE MACHINE

Electropump switch

Regulator burner

Detergent regulator

Pressure gauge

Burner switch

Pilot lights (OPTIONAL)

High pressure water outlet

Water inlet + filter

Gun

Lance

High pressure hose

Rubber hose fitting

Nozzle

Diesel tank

Detergent tank

>  CONTROL COMPONENTS
CONTROL SWITCHES

①  

Motor pump switch

②  

Burner switch with regulator

③  

Detergent regulator

⑤  

Burner switch

⑥  

Pilot lights: DIESEL shortage (OPTIONAL)

⑥  

A

:  Motor pump ON green pilot light

⑥  

B

: Leak pilot light

   -  flashes  when  the  pistol  lever  is  repeatedly 

operated in a short time or when a leak occurs 

in  the  high  pressure  circuit.  Remove  the  leak, 

referring to an authorized service centre.

   -  remains  ON  when  the  machine  is  left  in 

stand-by for over 20 minutes.

  Switch on and off the motor pump switch.

⑥  

C

: Burner switch

   -   flashes when the gasoil tank is empty; the 

burner is stopped. Refuel.

   -  remains ON when the burner switches on.

  

                       (if fitted)

 

IMPORTANT:

 

This water cleaner is equipped 

with the A.S.S. (Automatic Stop System), which 

stops the machine during the bypass phase. 

To start the water cleaner, it is therefore necessary 

to  set  the  switch  on  position  “ON”;  after  that 

press  the  pistol  trigger:  the  Automatic  Stop 

System  will  start  the  machine  and  will  stop  it 

automatically  when  the  trigger  is  released.  It 

is  advisable  to  put  on  the  safety  of  the  pistol 

trigger  whenever  the  machine  is  stopped,  in 

order to avoid unintentional starting.

•  Any  automatic  start  of  the  machine  without 

pressing  the  gun  trigger  is  attributable  to 

air  bubbles  in  the  water  or  other  similar 

phenomena which do not imply the existence 

of any defects in the machine. 

•  Do not leave the appliance unattended during 

the standby for more than 5 minutes. Contrarily, 

for the safety of the appliance it is necessary to 

re-turn the switch into the OFF position.

•  Please  check  that  the  coupling  of  the  high 

pressure  hose  with  the  appliance  and  the 

gun  supplied  as  standard  equipments  made 

correctly, that is to say without any water leak.

If  the  appliance  is  equipped  with  a 

pressure 

regulator

:

•  when the pressure is set to minimum the A.S.S. 

may  not  trigger.  Therefore,  do  not  allow  the 

appliance to function in by-pass for more than 

1 minute.

•  do not act on the gun lever too frequently (this 

may cause a malfunction).

>  INSTALLATION AND START-UP

(fig. 

A

)

FILLING UP WITH FUEL

Fill the tank with the fuel indicated on the technical 

data plate 

(Diesel)

Avoid that the tank is empty when the machine is 

running in order not to damage the fuel pump.

 WARNING:

 Incorrect fuel shall not used as they as 

provide hazard.

FILLING UP WITH  DETERGENT

the detergent tank with the suggested products, su-

itable for the kind of washing to be carried out.

 WARNING: 

Make use only of liquid detergent, do not 

absolutely use acid or too much alkaline products. We 

suggest you to make use of our products, which have 

been studied for the use with  washer machines.

>  INSTALLATION

(fig. 

CDEFG

)

•  Check  that  the  master  switch  is  turned  to 

EN

21

Summary of Contents for NPX XP

Page 1: ...stru es antes da utiliza o HUOMIO lue ohjeet ennen k ytt PA NJA prije upotrebe pro itajte upute POZOR pred uporabo preberite navodila Thecnical data plate Placa dato t cnicos IDROPULITRICE AD ALTA PRE...

Page 2: ...EET GLAVNI KOMANDNI DIJELOVI GLAVNI DELI ZA UPRAVLJANJE XP LP fig A A B C In base al modello si possono verificare delle differenze nella fornitura Depending on the model there are differences in the...

Page 3: ...ER PRINCIPALES RGANOS DE CONTROL HOOFDSCHAKELAAR PRINCIPAIS RG OS DE COMANDO P OHJAUSLAITTEET GLAVNI KOMANDNI DIJELOVI GLAVNI DELI ZA UPRAVLJANJE Diesel Detergent Consoante o modelo existem diferen as...

Page 4: ...2 INSTALLAZIONE INSTALLATION MISE EN PLACE INSTALLATION INSTALACI N INSTALATIE INSTALA O ASENNUS INSTALACIJA MONTA A fig C fig B optional 1 2 inch 13 mm 5 40 C min 30 l min max 1 MPa fig D fig E fig F...

Page 5: ...umie wachlarzowy pahlja asti curek vode solfj dersformad str le mlaznica raspr iva jet evantai jet fan getto spillo ventaglio spread pattern pencil jet jet variable vario Duese chorro regulable dunnes...

Page 6: ...6 Diesel 4 5 fig L 1 2 3 6 7...

Page 7: ...A ESQUEMA H DRICO WATERSCHEMA ESQUEMA HIDR ULICO VEDENKYTKENT KAAVIO SHEMA VODENOG KRUGA VODOVODNA SHEMA H2O IG 1 M3 TS EV TR IB M2 GG L1 SCHEMAELETTRICO ELECTRICDIAGRAM SCHEMAELECTRIQUE ELEKTROSCHEMA...

Page 8: ...LKX_LP_1Ph_230V LKX_LP_3Ph_400V 8...

Page 9: ...s or chemicals may put the appliance s safety at risk 05a WARNING Do not use the machine within range of persons unless they wear protective clothing 05b Do not allow other people or animals within a...

Page 10: ...21WARNING Risk of explosion Do not spray flammable liquids 22WARNING To ensure machine safety use only original spare parts from the manufacturer or approved by the manufacturer 23WARNING Do not dire...

Page 11: ...e unit before operation Unscrew the high pressure line at the high pressure outlet of the unit Switch on the unit and let it run until water free of bubbles emerges at the high pressure outlet Switch...

Page 12: ...in order to avoid unintentional starting Any automatic start of the machine without pressing the gun trigger is attributable to air bubbles in the water or other similar phenomena which do not imply t...

Page 13: ...for the quantity required as described in the DETER GENT SUCTION section WARNING In case of operation indoors adequate ventilation and gas venting must be assured THERMOSTAT SET ABOVE 100 C USE WARNI...

Page 14: ...ditions BOILER CLEANING WARNING For all maintenance of the boiler of the high pressure pump and of the machine it is necessary to address to qualified personnel or to an authorized assistance center T...

Page 15: ...ves Check and clean the valves Check and or replace the setting valve area Replace the seals Fault Noisiness Cause Air suction The suction and or delivery valve springs are broken or down Foreign matt...

Page 16: ...not included in the warranty Parts subject to normal wear The high pressure tube and optional accessories Accidental damage caused by transport neglect or inadequate treatment incor rect or improper u...

Page 17: ...erungen sowie den Normen EN est en conformidad con las directivas CE y sus sucesivas modificaciones y tambi n con la norma EN in overeenstemming is met de Richtlijnen EG en latere wijzigingen daarop e...