4.4

 

COMPOSAVE SETTING ON TUNABLE WHITE VERSION 

Composave setting allow the user to work with restorative material avoiding their polymerization. 

Select the composave setting as described below: 

Joystick version option 1 

Joystick version option 2 

Visual information 

 

 

 

 

 

 
 

 
 

 
At the command selection of 

compo save a wigwag beep will be 

heard. Indicator strip changes in 
orange. 

 
 

exit from the compo-save setting 
with a single click from Compo-

save Setting 

 

                                                    Sensor version             

Visual information 

 

 

 

 

 

 

4.5

 

MINIMUM INTENSITY SETTING ON SOLAR VERSION 

Joystick version 

Sensor version 

Visual Information 

 

 

 

 

4.6

 

AUTO-ON SETTING 

When the on-mode in set in on position the lamps turn on automatically (without a specific command from the user) when there is power supply. 

 

4.7

 

SWITCHING ON/ OFF THEIA  

 

The light on the fixed arm (secondary light) can be switched on/off and 
adjusted  in synchro-mode with the operatory light and its command. 

The secondary light can be manually operated using the button (7) on the 
fixed arm.  

If the secondary light is switched on after the operatory light, it will be 
automatically synchronized. 

If the secondary light is switched on with the operatory light switched off, it 

will be automatically settled at the maximum intensity. 
 

The light on the fixed arm is adjusted in synchro  mode with head, 
it cannot be adjusted independently. 

 
 

4.8

 

REMOTE CONTROL 

Make reference to the Dental Unit’s instruction for use the Dental Light from the Dental Unit’s control panel 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for EVA

Page 1: ......

Page 2: ...LE WHITE VERSION 7 4 4 COMPOSAVE SETTING ON TUNABLE WHITE VERSION 8 4 5 MINIMUM INTENSITY SETTING ON SOLAR VERSION 8 4 6 AUTO ON SETTING 8 4 7 SWITCHING ON OFF THEIA 8 4 8 REMOTE CONTROL 8 4 9 SYNCRO...

Page 3: ...nd the competent authority of the Member State in which the user and or patient is established 1 SYMBOLS USED 1 1 SYMBOLS USED IN THIS MANUAL WARNING The paragraphs marked with this symbol contain ins...

Page 4: ...ce and is intended for illuminating the oral cavity and oral structures of patients in dentistry In the normal use the device is positioned distance of 700mm from the operative area the distance for w...

Page 5: ...DIGIT Fixed Arm 4 DIGIT Light Source Integrated Camera 5 DIGIT Command radiofrequency RF 6 DIGIT Cables 7 DIGIT Custom 1 8 9 DIGIT 5 U 0 Only Head No arms 0 Only Head No arms 0 Tunable White 0 Joystic...

Page 6: ...eters are memorized by the lamp and made available at every switching on Last light intensity setting light colour temperature Setting for Tunable White variant Warning Do not use the device if parts...

Page 7: ...or light changes according to the illuminance level according to the images below Light Intensity Minimum Light Intensity Medium Minimum Light Intensity Medium Maximum Light Intensity Maximum 4 3 CHAN...

Page 8: ...hen the on mode in set in on position the lamps turn on automatically without a specific command from the user when there is power supply 4 7 SWITCHING ON OFF THEIA The light on the fixed arm secondar...

Page 9: ...Light it is necessary to repeat the procedure from point 1 3 After the blue LED switches on the room light there are 60 seconds to confirm the Pairing by pressing the programming button placed on the...

Page 10: ...arter 1 2 must be well secured and safety screws intact The screws under carter 3 must be well secured Yearly Carter 3 Carter 2 Carter 1 Service Engineer Check the absence of any oxidation into joints...

Page 11: ...es Never use detergents containing surfactants or water repellents that depositing can leave streaks Slight streaking will not prejudice the quality of the light Products differing from those suggeste...

Page 12: ...0 60 Hz 32 V dc 10 Max Power 24 V ac 26 VA 32 V dc 14 VA 24 V ac 40 VA 32 V dc 28 VA Recommended fuses for installation not supplied in charge to installation 24 V ac T1 6AL 250V 32 V dc T1 25AL 250V...

Page 13: ...IONS The device in the original packaging can be transported and stored for a maximum period of 15 weeks if the following environmental conditions are met Environmental temperature from 20 C to 70 C R...

Page 14: ...EVA USER MANUAL EN Edition 1 0 April 2020 Pag 14 di 14...

Reviews: