Faro EVA User Manual Download Page 3

EVA           

 

USER MANUAL - EN 

Edition 1.0 April 2020    

 

 

 

 

 

 

                                      Pag. 3 di 14 

              

 

Dear Customer, 
FARO hopes you enjoy your work with the new high quality light. For safe work and to take full advantage of the performance of the product, read carefully 

this manual before using the device.  

In particular, follow all the warnings and the notes described into the Safety Recommendations included in the Packaging. . 
 

Warranty Conditions: 
FARO offers the final customer a 

24 month warranty

 starting from the date of installation until a maximum of 30 months from the manufacturing date.  

Repairs under warranty must be performed by FARO or its approved Service network. 

Warranty is considered valid only when: 

 

the user sent the Certificate of Warranty duly filled out at the following email: [email protected]  

 

the user registered the warranty throughout the Faro website; 

 
The warranty covers manufacturing  and engineering  defects; in case of valid claims, the  warranty   covers free parts replacement only.  Manhour work is not 

included in the warranty.  
The warranty  is not considered valid, at the sole discretion of FARO, if the fault is due to tampering, damage,  unauthorized changes to the product, incorrect 

use, improper maintenance and normal wear and tear. 

 
This product have a Service Life of: 10 Years. 

 
Any serious incident occurring in relation to the device should be reported to the Manufacturer and the competent authority of the Member State in which the 

user and/or patient is established. 

 

1

 

SYMBOLS USED 

1.1

 

SYMBOLS USED IN THIS MANUAL 

 

WARNING 

The paragraphs marked with this symbol contain instructions that must be carefully followed to avoid 
damaging the device, harming the operator or the patient. 

 

 

CAUTION 

These instructions warns you that you must pay attention to avoid situations that could damage the device. 

 

 

FORBIDDEN 

This icon highlights what you should not do to avoid damaging the device. 

 

 

NOTES 

This icon supplies information that allows you to use the device more efficiently. 

 

1.2

 

SYMBOLS USED IN THE LABELLING AND ON THE PACKAGING 

The data plate is fixed: 

• for the complete light or arms: on the rear arm 

• for the head: under the heat sink cover 
Serial Number description 

 

For dental light YY

LD

NNNNNN 

 

For head of dental light YY

TE

NNNNNN 

Where  

 

YY: last two digit of the year of manufacturing 

 

NNNNNN: progressive counter of the year  

e.g.: 21LD000001 I the first product manufactured in 2021. 
 

The following standardized symbols are also present: 

Symbol 

Description 

 

Mark for Conformitè Europe 

 

Medical Device according to Regulation (EU) 2017/745 of the European Parliament and of the Coucil of 5 April 2017 on 

medical devices, 

 

Read the instructions use. Supplied by Electronic means. 

 

Manufacturer symbol according to Regulation (EU) 2017/745 

 

The instructions for use include safety warnings 

 

WEEE equipment according to the Directive 2012/19/EC. Dispose of 
the product according to this directive. 

 

Double insulation. Class 2 device against electrical risk 

Summary of Contents for EVA

Page 1: ......

Page 2: ...LE WHITE VERSION 7 4 4 COMPOSAVE SETTING ON TUNABLE WHITE VERSION 8 4 5 MINIMUM INTENSITY SETTING ON SOLAR VERSION 8 4 6 AUTO ON SETTING 8 4 7 SWITCHING ON OFF THEIA 8 4 8 REMOTE CONTROL 8 4 9 SYNCRO...

Page 3: ...nd the competent authority of the Member State in which the user and or patient is established 1 SYMBOLS USED 1 1 SYMBOLS USED IN THIS MANUAL WARNING The paragraphs marked with this symbol contain ins...

Page 4: ...ce and is intended for illuminating the oral cavity and oral structures of patients in dentistry In the normal use the device is positioned distance of 700mm from the operative area the distance for w...

Page 5: ...DIGIT Fixed Arm 4 DIGIT Light Source Integrated Camera 5 DIGIT Command radiofrequency RF 6 DIGIT Cables 7 DIGIT Custom 1 8 9 DIGIT 5 U 0 Only Head No arms 0 Only Head No arms 0 Tunable White 0 Joystic...

Page 6: ...eters are memorized by the lamp and made available at every switching on Last light intensity setting light colour temperature Setting for Tunable White variant Warning Do not use the device if parts...

Page 7: ...or light changes according to the illuminance level according to the images below Light Intensity Minimum Light Intensity Medium Minimum Light Intensity Medium Maximum Light Intensity Maximum 4 3 CHAN...

Page 8: ...hen the on mode in set in on position the lamps turn on automatically without a specific command from the user when there is power supply 4 7 SWITCHING ON OFF THEIA The light on the fixed arm secondar...

Page 9: ...Light it is necessary to repeat the procedure from point 1 3 After the blue LED switches on the room light there are 60 seconds to confirm the Pairing by pressing the programming button placed on the...

Page 10: ...arter 1 2 must be well secured and safety screws intact The screws under carter 3 must be well secured Yearly Carter 3 Carter 2 Carter 1 Service Engineer Check the absence of any oxidation into joints...

Page 11: ...es Never use detergents containing surfactants or water repellents that depositing can leave streaks Slight streaking will not prejudice the quality of the light Products differing from those suggeste...

Page 12: ...0 60 Hz 32 V dc 10 Max Power 24 V ac 26 VA 32 V dc 14 VA 24 V ac 40 VA 32 V dc 28 VA Recommended fuses for installation not supplied in charge to installation 24 V ac T1 6AL 250V 32 V dc T1 25AL 250V...

Page 13: ...IONS The device in the original packaging can be transported and stored for a maximum period of 15 weeks if the following environmental conditions are met Environmental temperature from 20 C to 70 C R...

Page 14: ...EVA USER MANUAL EN Edition 1 0 April 2020 Pag 14 di 14...