16
│
25
Manual
KULTIS 6 | KULTIS 8
Pressure Regulation Valve
The valve is used to set the pressure in the pump which prevents spontaneous flow of the fluid
through the pump. The correct setting of the valve must be within the range of 5
– 10 on the
scale. Do not exceed the value of 10 on the scale.
Pressure Change Valve
Position A: Fast filling of the machine hoses (empty hoses)
Position C: Pressure position
Possibility of filling position C
– longer period
When machine in operation
– position C
Pump Air Chamber
The air chamber eliminates the pressure surge in the fluid. The boost pressure of the air
chamber is 1/3 of the operating pressure at 1000kPa; the air chamber has pressure of 300kPa.
Maintenance of the Pump after Season
Rinse the distribution with clean water and empty the tank and the hoses. Disconnect the
hoses from the pump and run the drive which drains water from the pump. Uninstall the filter;
drain tanks.
Pump Safety Valve
The pump is equipped with a safety valve in case that the pressure in the pump increases.
The opening pressure of the safety valve is 20bar.
Fig. 3 Pump Safety Valve
Pump safety valve