• Position the primary air regulator into the open position,
• open the hearth door,
• put the necessary fuel into the hearth (ungreased paper, small pieces of wood),
• Ignition is performed,
• The hearth and ashtray door is closed,
• After the initial flame, wider wood logs should be put into the hearth, the hearth door is closed, the draft is reduced to
half, and the regulator handle is positioned into the front position (Image 5).
IMPORTANT: When opening the stove door, due to high temperatures on the stove handles, you must use the
protective glove which is delivered with the stove.
Fuels like petrol or light distillate oil and similar fuels must not be used, because they can lead to stove damaging and
explosion.
Among the others, the following cannot be burnt: organic waste, food leftovers, used and painted wood, plastic objects,
flammable and explosive materials the combustion of which disturbs proper operation of the stove and can cause
damage and environment pollution.
High outside temperatures may cause bad airflow (draft) in the chimney, so it is recommended to put smaller quantities
of fuel more frequently.
6. STOVE OPERATION
We recommend to split the quantity of fuel into half and to gradually heat the stove when used for the first time, in order
to control and test the operation.
Maximum quantity of wood for safe operation is 2,5kg (5.5lbs).
The hearth door should be opened only when necessary, in order to add new quantity of wood. The next quantity of
wood is added only after the previous quantity has been burned.
Do not allow the obstruction caused by ashes and unburned fuel. Clean the obstruction. The door should be opened
slowly, without abrupt moves, in order to allow the pressures in the hearth and the room to become equal. In that way
you prevent the exit of smoke and flame from the hearth.
The hearth door must be closed when the stove is used.
The wood should have maximum 20% humidity. In addition to bad combustion effect, wet wood leaves deposits on the
glass.
The ashtray should be regularly cleaned so there is always space for ashes and the ash must not be allowed to reach
the grid level, otherwise the air cannot flow into the combustion chamber.
The handle of the regulator of gases flow used for the selection of the regime of the stove operation has two positions.
1. for lighting the fire and cooking, the handle
should be pulled out, as well as when adding a
new quantity of fuel.
2. When it is used simultaneously for cooking,
baking and heating or just for heating, the handle
of regulator of gases flow is pushed inside (see
picture).