Regulation of primary air
The primary air control should be put in the opened
positionduring lighting and kept that way till the moment of
the establishment of the stabile operation of the stove after
putting larger pieces of wood. After that the regulator
should be put in the closed position and held in that position
during the stove operation. When the regulator is closed it
prevents the air flow under the grid by which it lessens the
combustion intensity. If you want fast fuel combustion, open
the primary air control.
Opened
Closed
Regulation of secondary air
The secondary air regulator should be put in the position
closed during ignition and held in that position until you
establish the operation heating regime. After that, put the
closed
regulator into the position opened and hold it in that position
during the stove is in operation. The secondary air is used to
clean the glass on the hearth door and for better combustion.
During the stove operation, the movable part of the regulator is
heated, so use the additional equipment during regulation.
Opened
7. CLEANING THE STOVE
We recommend removing the ash produced every day. Never allow the ash accumulate to the point where it touches the
grate; this would obstruct the circulation of primary air and slowly suffocate the fire.
When cleaning the outside surfaces of the stove, avoid abrasive products which would damage the protective paint. Do
not use chemicals that contain diluents, because the cast parts are protected by heat resistant paint.
Panoramic door glass should be cleaned with normal detergent and exclusively after getting cold. Do not use abrasive
products because you will damage the glass surface. After cleaning, rinse with pure water and dry.