3
ALL C-21B MODELS:
DRYER BODY EXPANDS FROM
8’ TO 11’ WITH HEAT RECLAIMER
*
*
*
NOTE 1:
2’ LEG HEIGHT IS STANDARD.
OTHER HEIGHTS ARE AVAILABLE.
SEE
NOTE 1
Fig. 1-1 C-2100B Series dimensions
Model
C-2130B
C-2140B
C-2160B
C-2175B
C-21100B
‘A'
9'-6"
9'-6"
10'-11"
10'-11"
10'-11"
‘B'
20'-0"
26'-0"
34'-0"
34'-0"
38'-0"
‘C'
33'-3"
39'-3"
48'-8"
48'-8"
52'-8"
‘D'
37'-0"
43'-0"
52'-0"
52'-0"
56'-0"
Leg Pairs Required
Body Fan-Heater
3
2
4
2
5
2
5
2
5
2
C-2130 & 40B
WITH HEAT
RECLAIMER
C-2160, 75B, & 100B
FAN-HEATER MODULE
C-2100B and C-2100B1
Two model
types, each dedicated to ultra-efficient
operation.
Models C-2130B, C-2140B, C-2160B,
C-2175B, and C-21100B for Dry &
Cool: Designed for drying in the top 2/3
of the grain column and vacuum cooling
in the lower 1/3 of the grain column,
thus reclaiming the heat in the grain to
preheat the drying air.
Models C-2130B1, C-2140B1, C-
2160B1, C-2175B1, and C-21100B1
for Full Heat: Designed for Continuous
Flow Full Heat drying, using a single
plenum chamber with full grain column
exposure, as required for maximum dry-
ing capacity.
Field Conversion:
Converter pack-
ages are available to permit conversion
from Full Heat to Dry & Cool (pressure
or vacuum cooling).
GRAIN COLUMNS:
Two 14" galva-
nized steel grain columns. Solid column
dividers every two feet. Grain move-
ment through columns is controlled by
advanced electronic variable speed
metering roll drive control.
AUGERS: Automatically controlled top
leveling auger. Bottom auger unloads
grain discharged from metering rolls.
Heavy-duty construction.
BURNER MODULATION: Gas flow to
the burner is modulated to maintain the
desired plenum temperature using a
digital electronic proportional controller.
MOISTURE CONTROL:
Automatic
moisture control system uses digital
electronic proportional controller to
modulate meter roll speed.
AUTOMATIC CONTROL:
Automatic
control of loading, drying, cooling, and
discharge functions. Full safety control
system; automatic shutdown on wet
grain outage, grain Hi-Limit, and dis-
charge safety shutoff. Safety circuit
shutdown indicators.
Summary of Contents for C-2130B
Page 22: ...20...
Page 36: ...34 Fig 6 3 LP vaporizer assembly Fig 6 4 ASC control panel...
Page 49: ...Fig 8 1 Power circuit 220V 3 PH for C 2130B C 2140B C 2160B only 47 4B0280A TIF...
Page 50: ...48 Fig 8 2 Power cirucit 220V Part wind start for C 2175B C 21100 models only 4B0280C TIF...
Page 51: ...49 Fig 8 3 Power circuit 440V 3 PH for all C 2100B models 4B0280B TIF...
Page 52: ...Fig 8 4 Control circuit all models except part wind start p 1 of 3 50 4B0280D TIF...
Page 53: ...Fig 8 4 Control circuit all models except part wind start p 2 of 3 51 4B0280E TIF...
Page 55: ...Fig 8 5 Control circuit part wind start models only p 1 of 3 53 4B0280H TIF...
Page 56: ...Fig 8 5 Control circuit part wind start models only p 2 of 3 54 4B0280I TIF...
Page 58: ...Fig 8 6 Safety circuit portion of control circuit all models 56 4B0280G TIF...
Page 65: ......