DRYING TABLES — C-2175B
The above drying capacities are estimates based on drying principles, field results, and computer simulations. Variances may occur
due to the grain’s physiological factors (kernel size, chemical composition, variety, maturity), escessive fines, weather conditions, etc.
CORN ...dry & cool
190 °F
210 °F
230 °F
% Unload
Dry
Capacity
% Unload
Dry
Capacity
% Unload
Dry
Capacity
in
out
Rate
Tim e
Dry Bph
Rate
Tim e
Dry Bph
Rate
Tim e
Dry Bph
17
15
73
19
1688
83
16
1929
18
15
55
25
1272
63
21
1454
19
15
45
30
1037
51
26
1185
58
23
1333
20
15
38
35
881
43
31
1007
49
28
1133
21
15
33
41
766
38
36
875
43
32
985
22
15
29
46
675
33
41
771
37
36
868
23
15
26
52
599
30
46
685
33
41
770
24
15
23
58
534
26
51
611
30
45
687
25
15
21
65
478
24
57
546
27
51
614
26
15
19
73
428
21
64
490
24
57
551
27
15
17
81
385
19
71
440
21
63
495
28
15
15
90
347
17
79
396
19
70
446
29
15
14
100
313
15
87
358
17
78
403
30
15
12
110
284
14
96
325
16
86
365
31
15
11
121
259
13
106
295
14
94
332
32
15
10
132
236
12
116
270
13
103
304
33
15
9
144
217
11
126
248
12
112
279
34
15
9
156
201
10
136
230
11
121
258
35
15
8
167
187
9
146
213
10
130
240
CORN ...full heat
190 °F
210 °F
230 °F
% Unload
Dry
Capacity
% Unload
Dry
Capacity
% Unload
Dry
Capacity
in
*out
Rate
Tim e
Dry Bph
Rate
Tim e
Dry Bph
Rate
Tim e
Dry Bph
18
17
86
23
1998
99
21
2284
19
17
70
29
1626
80
25
1858
90
22
2090
20
17
60
34
1384
68
30
1582
77
26
1780
21
17
52
39
1207
60
34
1380
67
30
1552
22
17
46
44
1067
53
38
1219
59
34
1372
23
17
41
49
949
47
43
1084
53
38
1220
24
17
37
55
846
42
48
967
47
43
1088
25
17
33
62
756
37
54
864
42
48
972
26
17
29
69
677
33
61
773
38
54
870
27
17
26
77
607
30
68
693
34
60
780
28
17
24
86
545
27
75
623
30
67
701
29
17
21
95
491
24
83
561
27
74
632
30
17
19
105
445
22
92
508
25
82
572
31
17
17
116
404
20
101
462
22
90
520
32
17
16
127
370
18
111
423
21
99
476
33
17
15
138
341
17
120
389
19
107
438
34
17
14
148
316
16
130
361
18
115
406
35
17
13
159
295
15
139
338
16
123
380
*represents the target moisture out of the dryer. Expected final moisture in the bin is 15.0%
Based on 100% Unload rate of
2315 bph
MOISTURE
MOISTURE
Summary of Contents for C-2130B
Page 22: ...20...
Page 36: ...34 Fig 6 3 LP vaporizer assembly Fig 6 4 ASC control panel...
Page 49: ...Fig 8 1 Power circuit 220V 3 PH for C 2130B C 2140B C 2160B only 47 4B0280A TIF...
Page 50: ...48 Fig 8 2 Power cirucit 220V Part wind start for C 2175B C 21100 models only 4B0280C TIF...
Page 51: ...49 Fig 8 3 Power circuit 440V 3 PH for all C 2100B models 4B0280B TIF...
Page 52: ...Fig 8 4 Control circuit all models except part wind start p 1 of 3 50 4B0280D TIF...
Page 53: ...Fig 8 4 Control circuit all models except part wind start p 2 of 3 51 4B0280E TIF...
Page 55: ...Fig 8 5 Control circuit part wind start models only p 1 of 3 53 4B0280H TIF...
Page 56: ...Fig 8 5 Control circuit part wind start models only p 2 of 3 54 4B0280I TIF...
Page 58: ...Fig 8 6 Safety circuit portion of control circuit all models 56 4B0280G TIF...
Page 65: ......