EUTSCH
INDEX
Introduction 16
Installation and connection
17
Operating functions
20
Operating instructions
20
Operations 21
SAFETY NOTICES
Read the instructions contained in this manual carefully
because they provide important information about safe
installation, use and maintenance. Keep this manual ap-
propriately for future reference.
Install your switchboard in a dry place away from heat
sources or devices that produce heat and magnetic fields.
Do not clean the switchboard with water or chemical
solvents, use a dry cloth for cleaning.
This device must be exclusively operated for its intended
use. The manufacturer cannot be held responsible for
possible damage caused by improper, erroneous and
unreasonable use.
Keep packing parts away from children (i.e. plastic bags,
expanded polystyrene, etc.).
Do not open the device when it is ON.
The installation must be made by specialized personnel
in compliance with the regulations in force.
Always refer to specialized personnel in case of break-
down, irregular operation or change in the installation.
The device complies with the rules for CE marking.
Technical data
Power supply directly from the line
Operating current:
Max: 0.5A
Stand by:
0.05A
OFF (night):
0.02A
Permanent memory for programming data
Directory capacity
500 names
LCD Display:
matrix 64x128 points
LED’s: 8
Alphanumerical keypad:
15 buttons
Service buttons:
7
Internal relay:
1
Maximum load contacts relay: 12Vac/12÷24Vdc - 1A
Operating temperature:
0° ÷ +50°C
Maximum admissible humidity: 90%RH
Note.
All devices connected in a system where
there is a switchboard must be labelled PDX1 or
higher.
A
J
T
G
P
W
D
M
B
K
U
H
Q
X
E
N
C
L
V
I
R
Y
S
Z
F
O
1
4
7
2
5
8
0
3
6
9
View with additional monitor.
To get pictures from the door stations it is possible to install
the monitor art.
ST7100CW
, the wall bracket art.
WB7262
and the table adaptor art.
TA7100W.
No additional program-
ming is required when installing the ST7100CW monitor.
Connection of a CCTV monitor
It is also possible to place a CCTV monitor with analogue
input near by PDX2000.
Attention!
Please use a monitor with no earth connection
(Class II) or use a ground loop separator. CCTV monitor can
work either in
continuous
or
timed mode
. In the case of
continuous
mode (direct powering from the mains) moni-
tor is always powered-ON even when the door station is
not in operation (no image).
In
timed
mode monitor is powered-ON only when the door
station is in connection (with image). To operate in this
way it is necessary to connect the CCTV monitor as shown
in the following diagram and program the internal relay of
switchboard as reported in the chapter “Operating mode
of internal relay”
.
CCTV MONITOR
Monitor power supply
PDX2000
max.12Vdc
V
M
C
NC
NO