2. Lift the cage unit using a winch or other lifting equipment, completely extracting the third
extension (part of the cage unit) from the column and remove the four pads (3) on it;
3. Remove all the pads (4) present (4 on each side) in the upper part of the second extension,
fully extract it from the column and remove the four pads (5) in its lower part;
4. Remove all the pads (6) present (4 on each side) in the upper part of the first extension (directly
connected to the machine base);
5. Remove the old layer of grease and clean all the surfaces.
3
5
4
6