![Faraday 12530-120 Owner'S Manual Download Page 42](http://html1.mh-extra.com/html/faraday/12530-120/12530-120_owners-manual_544401042.webp)
1 2 5 3 0 / 1 2 5 4 0 O W N E R ' S M A N U A L
P/N 447203 Issue I
V-3
PRIMARY AND SECONDARY POWER WIRING
The AC main connections and the battery connections must be made along the left-hand side of the
board. Route all high voltage and non-power limited wiring together and away from power limited wiring.
PRINTER WIRING
The printer connections must be made along the right-hand side of the board. The RS232 output
provides event data for connection to a printer, terminal or computer.
Faraday RPR-100
DIP Switch Settings
Control Board
Serial Board
Switch Bank 1
Serial Board
Switch Bank 2
SW-1
ON-Language (Unlashed 0)
ON-Odd Parity
ON-4800 bps
SW-2
OFF-Language (Unlashed 0)
ON-No Parity
OFF-4800 bps
SW-3
OFF-Language (Unlashed 0)
ON-8 Bit Data
ON-4800 bps
SW-4
OFF-Form Length (11”)
ON-Ready/Busy
OFF-DSR Inactive
SW-5
ON-Form Length (11”)
ON-Diagnostic-Circuit Test
ON-Buffer Threshold (32 bytes)
SW-6
ON-Auto Line Feed (ON)
ON-Normal Print Mode
OFF-Busy Signal Timing (1S)
SW-7
ON-Data Bits (8)
ON-DTR
ON-DTR Signal (space after power on)
SW-8
ON-Front Panel (Disable)
ON-DTR
OFF-Not Used
24V Battery Set
(7 to 38AH)
Supervised
Non-Power Limited
120VAC/240VAC 50/60Hz
3A/1.5A max., Supervised
Non-Power Limited
AC
N
GND
Keep All Non-Power Limited Wiring
Separate from Power Limited Wiring
B+
B-
Control unit
Function
Printer
Function
Printer or
Terminal
Printer or
Terminal
Computer
Male
9-Pin
Male
25-Pin
Female
9-Pin
CTS
DTR
8
20
4
TXD
RXD
2
3
2
RXD
TXD
3
2
3
GND
GND
5
7
5
Settings: 4800 bps, 8 data bits, 1 stop bit, no parity