english
31
If the room/zone does not need to be heated, the valve can be closed.
The valve is only opened if there is a risk of frost. The calci
fi
cation
protection function continues to run.
To activate this, proceed as follows
• In manual operation (
Manu
) press the (
-
) button until “
OFF
” is
shown on the display.
• To
fi
nish, exit manual operation (
Manu
) or press the (
+
) button
until the desired temperature is set
Note: if this operation is setting, all taught-in radiator thermostats will
adjust to this setting.
13. SETTING VALVE PROTECTION FUNCTION (OFF)
Note: if this operation is setting, all taught-in radiator thermostats will
adjust to this setting.
When using the weekly thermostat, the settings can be made in the
con
fi
guration menu.
The menu items are selected with the (
+
) and (
-
) button and con
fi
rmed
with the “
OK
” button. A subsequent pressing of the “
Mode
” button
reverts to the previous level.
Il menu è composto dalle seguenti voci:
Pro:
Set the week program (see section 14.1)
dAt:
Change date and time (see section 6)
bOS:
Set valve opening and length of “Boost” function
(see
section14.5)
AEr:
Set “Open window temperature” for automatic
temperature decrease during airing (see section 14.8)
dEC:
Set valve protection function (see section 14.7)
t-d:
Switch time and date display (see section 14.2)
S-A:
Change display of nominal and actual value (section 14.3)
dSt:
Set automatic switching hour between summer and
winter (see section 14.9)
tOF
:
Set temperature offset (see section 14.10)
14. SETUP MENU (MENU)