8. TEACHING-IN OF O81RF RADIATOR THERMOSTATS
9. TEACHING-OUT OF WIRELESS COMPONENTS (UnL)
The C801 weekly thermostat can control up to eight O81RF radiator
thermostats. Therefore, all devices are taught-in to the weekly
thermostat directly. These then take over the settings of the weekly
thermostat (e.g. mode, temperature, week program). To teach in,
proceed as follows:
• Start by switching the teach-in O81RF radiator thermostat to
teach-in mode;
• Activate the teach-in mode of the C801 weekly thermostat.
• Press and hold down the
OK
button.
The antenna symbol “
” and
the remaining teach-in time (30
seconds) will be displayed.
If teach-in has been successful,
the weekly thermostat will
change back to normal operating
mode.
To unlearn, proceed as follows:
• Press and hold down the mode button for more than three
seconds.
• Select the “
UnL
” menu item with the (
+
) and (
-
) buttons and
con
fi
rm your entry using the
OK
button.
• “
ACC
“ (accept) appears on the display; con
fi
rm your entry using
the
OK
button.
After the “
UnL
“ function all connected O81RF thermostats are deleted
from the C801 weekly thermostat; factory setting is not mandatory.