Fantech FKD 10 Installation And Maintenance Instructions Manual Download Page 5

5

dimensions and Wiring

 

Model 

a  c  d  e Weight

  FKD 8XL 

8  12

1

/

2

 15

1

/

2

 

19 lbs.

  FKD 10 

10  12

1

/

2

 12

1

/

2

 

18 lbs.

  FKD 10XL 

10  14 

15 

26 lbs.

  FKD 12 

12  14  12

1

/

2

 

24 lbs.

dimensional data

All dimensions in inches. 

3/4"

Motor

Leads

Brown

Black

Capacitor

(Ground)

L (Black)

N (White)

Supply

Voltage

Blue

Green/Yellow

Blue

Black

Brown

L1

L2

115 Volt single Phase fans

230 Volt single Phase fans

C

A

E
D

dimensions and Wiring 

(Models FKD 12XL, 14, 14XL, 16, 16XL, 18, 18XL, 20)

dimensional data

 Model 

a  a1  a2  B  B1  c 

H  Weight

 FKD12XL 

12  14  12  17

7

/

8

 20

1

/

4

 18

7

/

8

 

7

/

8

 1

5

/

8

 4 8

3

/

4

 

3

/

8

  45 lbs.

 FKD14 

14  14  12  19

3

/

4

 22

1

/

8

 17

1

/

4

 1  1

5

/

8

 4 6

3

/

4

 

3

/

8

  45 lbs.

 FKD14XL 

14  16  14  19

3

/

4

 22

1

/

8

 20

1

/

4

 1

1

/

2

 1

5

/

8

 4 8

3

/

4

 

3

/

8

  55 lbs.

 FKD16 

16  16  14  19

3

/

4

 22

1

/

8

 18

3

/

4

 1

1

/

2

 1

5

/

8

 4 7

1

/

8

 

3

/

8

  55 lbs.

 FKD16XL 

16  18  16  22

1

/

8

 24

3

/

8

 23

1

/

4

 1

1

/

4

 1

5

/

8

 7

7

/

8

 8

1

/

2

 

1

/

2

  85 lbs.

 FKD18 

18  18  16  22

1

/

8

 24

3

/

8

 21

3

/

4

 1

1

/

4

 1

5

/

8

 7

7

/

8

 7 

1

/

2

  85 lbs.

 FKD18XL 

18  20  18  28

1

/

8

 30

3

/

8

 29

1

/

4

 2  1

3

/

4

 7

7

/

8

 12

1

/

2

 

1

/

2

  95 lbs.

 FKD20 

20  20  18  28

1

/

8

 30

3

/

8

 27

1

/

4

 2  1

3

/

4

 7

7

/

8

 10

1

/

2

 

1

/

2

  95 lbs.

115/230 Volt single Phase fans

Wiring schematic for 4 lead motors, single phase

notes:

1. All leads are color coded  

as well as identified with an  
Alpha/Alpha or Alpha/ 
 Numeric code (i.e. TK or  
Z2). This code may be  
shown as a band on the  
wire or on a schematic on  
the motor hub. Colors  
should be verified against 
code band. If code band and color do not correspond to schematics above, 
wire according to the code on the band.

2. Color of capacitor leads may be reversed. Fan operation will not be  

 affected.

230 Volt three Phase fan

notes:

1. Contactor should be used.  

Control coil should be  
 wired in series with motor  
thermal contacts (TK  
 leads) as shown in diagram  
to provide thermal motor  
protection.

2. All leads are color coded as well as identified with a band containing an 

Alpha/Alpha or Alpha/Numeric code (i.e. TK or Z2). Colors should be verified 
against code band. If code band and color do not correspond to schematics 
above, wire according to the code on the band.

Gray

Brown

L1

L2

460 Volt three Phase fan

Important note:  

For 460 volt operation, Orange (W2), Red (U2) and  
Grey (V2) wires must be spliced together.

notes:

1.  

Contactor should be used. 

 

Control coil should be wired  
in series with motor thermal  
contacts (TK leads) as 
shown  in diagram to pro-
vide thermal motor protec-
tion.

2.  All leads are color coded as well as identified with a band containing an 

Alpha/Alpha or Alpha/Numeric code (i.e. TK or Z2). Colors should be verified 
against code band. If code band and color do not correspond to schematics 
above, wire according to the code on the band.

contactor for 3-Phase fans, 208-230/460v

H

B1

B

A

F

G

C

A1 A2

D

D

All dimensions in inches.

L1

Incoming

3-Phase Supply 208/230/460

Control Power

for Contactor

AC Contactor

L2

L3

TK

TK

L1

L2

L3

L3

Ground

T1

T2

T3

C1

C2

Motor Leads

N / L2

L / L1

Summary of Contents for FKD 10

Page 1: ...Installation and Maintenance Instructions for MODEL FKD INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN MODÈLE FKD INSTRUCCIONES DE INSTALACION Y MANTENIMIENTO MODELO FKD ...

Page 2: ... pour une bonne combustion et pour l aspiration des gazs dans la cheminée afin d éviter des refoulements Suivez le guide de chauffage du fabriquant ainsi que les règles de sécurités comme celles qui sont éditées par l Association Nationale des Sapeurs Pompiers NFPA et l Association américaine des Ingénieurs pour le chauffage et l air conditionné ASHRAE ainsi que celles des autorités locales e Lors...

Page 3: ...unto de ventilador o impulsor 5 PRECAUCION Esta unidad contiene un impulsor expuesto No la utilice en sitios de fácil acceso por personas o animales USE PROTECCION PARA LAS MANOS Y CUIDESE DE CANTOS O BORDES AFILADOS 6 Hay que instalar rejillas de guarda al alcance del personal a menos de 7 pies del sitio de la obra o donde quiera que hagan falta para protección 7 FAVOR leer este manual por comple...

Page 4: ... section to complete installation Mounting Illustration 1 Vibratio n Mount Detail Please follow all applicable codes when installing this unit 1 Install wood supports to structure for fan mounting 2 If equipping with vibration mounts attach to supports 3 Attach fan to vibration mounts supplied by others be sure not to over tighten the neoprene element 4 If equipping fan with isolators FC Clamps th...

Page 5: ...ould be verified against code band If code band and color do not correspond to schematics above wire according to the code on the band 2 Color of capacitor leads may be reversed Fan operation will not be affected 230 Volt Three Phase Fan Notes 1 Contactor should be used Control coil should be wired in series with motor thermal contacts TK leads as shown in diagram to provide thermal motor protecti...

Page 6: ...l installation 1 Vibratio n Mount Detail Veuillez suivre tous les codes applicables à l installation de cet appareil 1 Installer les supports de bois à la charpente pour l installation du ventilateur 2 S il est équipé de support de vibration attachez les aux supports 3 Attachez le ventilateur aux supports de vibration fourni par d autres veillez à ne pas trop serrer l élément de néoprène 4 Si le v...

Page 7: ...asé en 230 volts Remarques 1 Le branchement doit être effectué par un professionnel La bobine de contrôle doit être branchée en série avec les contacts thermiques du moteur arrivées TK tel qu indiqué sur le schéma afin d assurer la protection thermique du moteur 2 Toutes les arrivées sont identifiées par la couleur de leur gaine et par une étiquette indiquant un code alpha alpha ou alphanumérique ...

Page 8: ...n Mount Detail Favor acatar todos los códigos del caso al instalar esta unidad 1 Monte los soportes de madera en la estructura para montar el ventilador 2 Si la instalación lleva tirantes antivibratorios monte la unidad en los mismos 3 Monte el ventilador en los tirantes antivibratorios provisto por otros tenga cuidado de no apretar demasiado el elemen to de neopreno 4 Si el ventilador se va a mon...

Page 9: ...ja 2 Puede que se hayan invertido los colores de los hilos Esto no afecta el funcionamiento del ventilador Ventilador Trifásico de 230 Voltios Notas 1 Se debe usar un contactor La bobina de control debe cablearse en serie con los termocontactos TK del motor conforme el presente diagrama a fin de asegurar la protección térmica del mismo 2 Todos los hilos están codificados a color e identificados co...

Page 10: ...t d usine en matière de qualité d exécution ou de matériau Il sera peut être nécessaire de retourner le produit à l usine Fantech accompag né d une copie du contrat de vente et du numéro d autorisation de retour POUR RETOURNER UN PRODUIT À L USINE VOUS DEVEZ Obtenir un numéro d autorisation de retour pour ce faire communiquer avec Fantech aux États Unis au numéro 1 800 747 1762 ou au Canada au num...

Page 11: ...efecto en el material o en la mano de obra Es posible que el producto deba ser devuelto a la fabrica Fantech juntamente con una copia de la constancia de compraventa e identificado con el número de RMA PARA DEVOLUCIÓN A FÁBRICA USTED DEBE Tener un número de Autorización de Devolución de Material RMA Esto se puede obtener llamando a Fantech ya sea en los Estados Unidos al 1 800 747 1762 en Canadá a...

Page 12: ... You may have additional rights which vary from state to state This warranty does not apply to any Fantech product or part which has failed as a result of faulty installation or abuse incorrect electrical connections or alterations made by others or use under abnormal operating conditions or misapplication of the product or parts We will not approve for payment any repair not made by us or our aut...

Reviews: