Rev.10
87/212
Line-Bar voltage difference:4 to 50 V (step 0.1 V)
Line-Bar phase difference: 2 to 90 °(step 0.1 °)
Line-Bar frequency difference: 0.06 to 10 Hz (step 0.01 Hz)
Synchro temporization: 0.02 to 300 s (step 0.01 s)
Phase B line voltage and busbar voltage. Modules and phases using DFT
-
Frequency using hardware circuit with the passing through zero detection.
Permission signal minimum time 150 ms
49T
Available through configurable inputs
Programmable
logic
control (PLC)
OR4, OR4_LATCH, OR4_PULSES, OR4_TIMERUP, OR4_PULSE, NOR4, NOR4_LATCH,
NOR4_TIMERUP, NOR4_PULSE, AND4, AND4_PULSES, AND4_TIMERUP, AND4_PULSE,
NAND4, NAND4_TIMERUP, NAND4_PULSE
86
Allows to latch (lock out) the contact trip due to programmable logic (PLC: OR_LATCH).
Settings tables
3 settings tables
Activated by general settings or by inputs
RTC
Capacitor charge time: 10 minutes
Operation without auxiliary voltage: 72 hours
Oscillography
16 samples/cycle
Oscillo starting configuration
5 records: 3 cycles pre-fault and 85 post-fault
COMTRADE IEEE C37.111-1991
4 analogue channels and 64 digital channels
Fault report
20 fault reports with 24 events in each
Configurable inputs
6 configurable inputs.
The voltage of the inputs is the same as the auxiliary power supply
Configurable outputs
4 configurable outputs:
250 V AC
– 8 A
30 V DC
– 5 A
Output 1 and output 2: Commuted ( NC + NO)
Output 3 and Output 4: NO
Frequency
50/60Hz
Voltage measurement
Phase voltages (V-A, V-B, V-C), calculated neutral voltage (3V-0), residual voltage (V-R) (*), Busbar
voltage (V-BB)(*), positive sequence voltage (V-1), negative sequence voltage (V-2), Maximum
voltage (Vmax) and Minimum voltage (Vmin)
Measurement range:
Low scale (rated voltage<250 V)
3-250 V
High scale (rated voltage>250V)
12-1000 V
Summary of Contents for SIL-V
Page 7: ...www fanox com Rev 10 7 212 2 DIMENSIONS AND CONNECTION DIAGRAMS 2 1 Equipment front view...
Page 8: ...www fanox com Rev 10 8 212 2 2 Equipment dimensions...
Page 9: ...www fanox com Rev 10 9 212 2 3 Cut out pattern...
Page 11: ...www fanox com Rev 10 11 212 3 VT configuration phase neutral...
Page 12: ...www fanox com Rev 10 12 212 3 VT configuration phase neutral residual voltage SILVxxxx0xxxxx...
Page 13: ...www fanox com Rev 10 13 212 3 VT configuration phase neutral busbar voltage SILVxxxx2xxxxx...
Page 14: ...www fanox com Rev 10 14 212 3VT configuration phase phase residual voltage...
Page 15: ...www fanox com Rev 10 15 212 2VT configuration phase phase residual voltage...
Page 17: ...www fanox com Rev 10 17 212 2 5 Terminals...
Page 25: ...www fanox com Rev 10 25 212 3 3 Functional Diagram...
Page 192: ...www fanox com Rev 10 192 212...
Page 211: ...www fanox com Rev 10 211 212 NOTES...
Page 212: ...www fanox com Rev 10 212 212...