Gn
22
g
Mains power supply
Mains voltage
24 V AC (± 10%)
Emergency power
24 V DC (± 10%)
Mains frequency
50/60 Hz
Maximum current
1.8 A
Power consumption
45W
Battery
2 x 12V DC
Inputs
Analog in
Voltage- or temperature measuring
Voltage 0-10V, 10-0V, temperature sensor
type SF.7 (-50°C to 110°C)
I/O network
Digital
PF (PowerFail)
Normally open contact
Position feedback actuator
CPS (contactless position sensor)
Limit switches
30Vac / 60Vdc , max 1A
Outputs
Alarm relay
30 V AC / 60 V DC, max. 2A
External alarm led
24 V DC
Actuator
Duty cycle
30%
Speed
0.95 rpm
Torque
Max. 60 Nm
Holding torque
Max. 40 Nm
Tensil strength
Cable winch drum / Belt drum ø50 mm
250 kg
Cable winch drum / Belt drum ø65 mm
190 kg (for use with a Fantura inlet)
Holding force
Cable winch drum / Belt drum ø50 mm
167 kg
Cable winch drum / Belt drum ø65 mm
127 kg (for use with a Fantura inlet)
Min.-max number of revolutions
0.7-2.7 rev
Min.-max stroke
Cable winch drum / Belt drum ø50 mm
11-40 cm
Cable winch drum / Belt drum ø65 mm
15-53 cm
Manual control
Auto/manual switch
Closed
– 0 – A – 0 - Open
Potentiometer input (for remote manual operation) and/or
8kΩ - closed, 0kΩ - open
Max. thermostat
∞ - no manual operation
Output / input type
Output type
iM.60 address sequence number
Air inlet position
"iM.60 address".01
Input type
Analogue measurement (temp.)
"iM.60 address".01
Air inlet position measurement
"iM.60 address".02