Shenzhen Hpmont Technology Co., Ltd.
Chapter 6 Function Introduction
MONT72 Series User Manual V1.0
- 67 -
Ref. Code
Function Description
Setting Range [Default]
F16.13
UPS running direction auto-determine enable
0 - 4 [0]
0: Not enabled.
1: Determine the running direction based on the current.
2: Determine the running direction according to the encoder direction.
3: Determine the running direction according to the current (no start compensation and zero speed hold).
4: Determine the running direction according to the encoder direction (no start compensation and zero speed
hold).
Note: 2 and 4 must select closed loop vector control (F00.01 = 2) and the elevator brake is controlled by MONT72.
F16.14
Running min. current limit
0 - 100 (F07.11) [20%]
F16.15
Running min. detect time
0.0 - 5.0 [0.0s]
When the elevator run current is less than F16.14 and duration exceed F16.05, MONT72 will alarm E0025 fault
(too small running current).
F16.16
Governor fault detection time
0.0 - 2.0 [1.0s]
When the detection terminal of governor detects signal and exceed F16.16, MONT72 alarms E0037 fault
(governor fault).
F16.17
DC braking current at stop
0 - 150 [100%]
F16.18
Starting frequency of DC braking current at stop
0.20 - 10.00 [0.50Hz]
F16.19
Brake release frequency
0.00 - 10.00 [0.00Hz]
F16.20
Start DC braking current
50 - 150 [100%]
F16.21
Start DC braking current duration
0.0 - 3.0 [0.50s]
F16.22
Output ground detection before operation
0,1 [0]
0: Detection.
1: Not detected.
6.2.17
F17: Fault Protect Parameters
Traction machine overheating fault (F17.00 - F17.02)
The thermistor input embedded in the stator coil of the motor can be connected to AI1. According to
this input, the motor can be overheated. For the connection diagram, refer to section 4.4.3 Terminals
Wiring, page 21.
Ref. Code
Function Description
Setting Range [Default]
F17.00
Input voltage at motor overheat
0.00 - 10.00 [0.00V]
F17.01
Thermistor type
0 - 2 [0]
0: Not detect the motor overheat (NC).
1: Positive charateristic (PTC).
•
When AI1 input exceeds F17.00, MONT72 alarms E0020 fault (motor overheat).
2: Negative charateristic (NTC).
•
When AI1 input is less than F17.00, MONT72 alarms E0020 fault (motor overheat).
6