F11: PG Parameters
In elevator application, the PG is necessary for the motor. Please refer to section 4.5 for PG.
Ref. Code
Function Description
Setting Range [Default]
F11.00
MONT72 PG interface board
1 - 4 [1]
1: HD-PG2-OC-FD is valid. Only for asyn. motor.
2: HD-PG6-UVW-FD is valid. Only for syn. motor.
3: HD-PG5-SINCOS-FD is valid. Only for syn. motor.
4: HD5L-PG1-SC is valid. Only for syn. motor. (support Endat)
F11.01
PG P/R
1 - 9999 [2048]
F11.02
PG direction setting
0,1 [0]
Defines the connection sequence of PG whether the same as that of the drive-motor connection.
•
In order to change the connection of AB two phases of the PG, you can change this parameter.
0: The same direction.
1: The reverse direction.
F11.03
PG signal filter coefficient
0x00 - 0x77 [0x11]
Unit: Low-speed filter coefficient.
Ten: High-speed filter coefficient.
F11.04
The protocol of serial communication PG
0 - 9 [0]
0: Endat.
1 - 9: Reserved.
F11.05
Detecting time of PG wire disconnection
0.00 - 2.00 [1.00s]
F11.05 specifies the duration time for detecting PG wire disconnection fault.
MONT72 detects the PG wire disconnection and the duration time exceeds F11.05, then the controller
reports E0031 fault (PG disconnection).
•
No detection will be conducted when F11.05 = 0.
6.2.13
F12: Digital I/O Terminal Parameters
Ref. Code
Function Description
Setting Range [Default]
F12.00
Input terminal filter time
0.000 - 1.000 [0.010s]
Defines filter time of digital input terminal and to set input terminal sensibility.
•
The input terminals are susceptible to interference which will result in misoperation, so F12.00 can be
increased. But too long filter time will affect sensibility.
F12.01
X1 terminal function
000 - 134 [1]
F12.02
X2 terminal function
000 - 134 [2]
F12.03
X3 terminal function
000 - 134 [3]
F12.04
X4 terminal function
000 - 134 [4]
F12.05
X5 terminal function
000 - 134 [5]
F12.06
X6 terminal function
000 - 134 [6]
F12.07
X7 terminal function
000 - 134 [0]
F12.08
X8 terminal function
000 - 134 [0]
F12.09
X9 terminal function
000 - 134 [0]
F12.10
X10 terminal function
000 - 134 [0]