2
IMPORTANT SAFETY INSTRUCTIONS
Read and follow all instructions in this owner’s manual and on the equipment. Failure to follow
instructions can cause severe injury and/or death.
Never operate or test the circulation system at more than 4 bar.
Never change the filter control valve position while the pump is running.
Hazardous Pressure. Due to the high operation pressure, some components from the pump or
the filter could be violently separated.
Do not operate the pool equipment if a system component is not assembled properly, damaged,
or missing.
1.
MAIN FEATURES
Our Volumetric filter (Fig.1) is a one-piece blow moulded filter made in high density
polyethylene material manufactured to maximize the strength of the filter.
Product dimensions:
1.1.
TECHNICAL FEATURES
Code
Model
No.
Filtration
area (m
2
)
Valve
connections
Max. working
pressure (bar)
Max. Flow
rate (m
3
/h)
Sand
(kg)
88016003
T450
0.16
1.5" / 50 mm
4 bar
8
75
88016004
T500
0.2
10
95
88016046
T600
0.29
14.6
165
88016007
T700
0.39
19.5
200
88016047 T600B
0.29
2" / 63 mm
14.6
165
88016008 T700B
0.39
19.5
200
Model
A
(mm)
B
(mm)
C
(mm)
T450
954
457
353
T500
1040 508
400
T600
1090 610
457
T700
1180 711
516
T600B
1142 610
457
T700B
1232 711
516
Fig 1. Volumetric filter
A
B
C