48
By default, presets will send both IA states and Global IA state programming when a preset is selected for the first time.
This means that the controller will evaluate all 60 IA Slots and determine what commands to send. If an IA switch is set
to ON, it will send the ON commands. If the IA switch is set to BYPASS, it will send the OFF commands. If the IA switch is
set to OFF (and the global BLOCK OFF MESSAGES is not set to “yes”), then it will send the OFF commands. If the BLOCK
OFF MESSAGES in the global menu is set to yes, it will BLOCK the OFF state and not send any messages for that
particular IA Slot. While the preset WILL update the actual state of the IA Slots (non-global), it will only process the IA
Slot commands based on the setting of this parameter.
Your options are to either (1) Not send any IA or Global IA commands, (2) Send only the non-global IA Slots, (3) send
only the Global IA slots, or (4) send both the IA and Global IA slots.
The global override setting allows the preset to replace the current global settings with that setting define in the Initial
IA State programming for the preset. While there are many uses, one obvious use would allow you to maintain global
buttons and define a “GLOBAL” preset which would force the global IA Slots to a known state. Perhaps several presets
are created with various “settings”- allowing for multiple “global” presets to be created and selected by the user.
IA Resend Type
IA & Global IA
IA Resend Type
Don’t send IA States
IA Resend Type
IA States Only
IA Resend Type
Global IA Only
IA Resend Type
IA & Global IA
Global Override
NO