background image

Specifications — Falk LTG

The values shown are typical and slight variations are permissible.
AMBIENT TEMPERATURE RANGE — –20°F (–29°C) to 250°F

(121°C). Min. Pump = 20°F (–7°C).
MINIMUM BASE OIL VISCOSITY — 3300SSU (715cST) @

100°F (38°C).
THICKENER — Lithium & soap/polymer.
CENTRIFUGE SEPARATION CHARACTERISTICS — ASTM

#D4425 (Centrifuge Test) — K36 = 2/24 max., very high

resistance to centrifuging.
NLGI GRADE (ASTM D-217) —

1

/

2

CONSISTENCY (ASTM D-217) — 60 stroke worked penetration

value in the range of 315 to 360 measured at 77°F (25°C)
MINIMUM DROPPING POINT — 350°F (177°C) minimum
MINIMUM TIMKEN O.K. LOAD — 40 lbs.
ADDITIVES — Rust and oxidation inhibitors that do not corrode

steel or swell or deteriorate synthetic seals.

Packaging

14 oz. (0,4 kg ) CARTRIDGES — Individual or case lots of 10

or 60.
35 lb. (16 kg )PAIL, 120 lb. (54 kg ) KEG & 400 lb. (181 kg)

DRUMS.

General Purpose Grease

Annual Lubrication — The following specifications and

lubricants for general purpose grease apply to Falk Steelflex

couplings that are lubricated annually and operate within

ambient temperatures of 0°F to 150°F (–18°C to 66°C). For

temperatures beyond this range

 (see Table 1),

 consult

the Factory.
If a coupling leaks grease, is exposed to extreme temperatures,

excessive moisture or experiences frequent reversals, more

frequent lubrication may be required.

Specifications — General Purpose Coupling

Lubricants

The values shown are typical and slight variations are

permissible.

DROPPING POINT — 300°F (149°C) or higher.
CONSISTENCY — NLGI No. 2 with 60 stroke worked

penetration value in the range of 250 to 300.
SEPARATION AND RESISTANCE — Low oil separation rate and

high resistance to separation from centrifuging.
LIQUID CONSTITUENT — Possess good lubricating properties

... equivalent to a high quality, well refined petroleum oil.
INACTIVE — Must not corrode steel or cause swelling or

deterioration of synthetic seals.
CLEAN — Free from foreign inclusions.

General Purpose Greases Meeting Falk

Specifications

Lubricants listed below are typical products only and should not

be construed as exclusive recommendations

.

INSTALLATION OF TYPE T10 STEELFLEX

TAPERED GRID COUPLINGS

Installation

Only standard mechanics tools, wrenches, a straight edge and

feeler gauges are required to install Falk Steelflex couplings.

Clean all parts using a non-flammable solvent. Check hubs,

shafts and keyways for burrs.
INTERFERENCE FIT HUBS — Furnished without setscrews. Heat

hubs to a maximum of 275°F (135°C) using an oven, torch,

induction heater or an oil bath. To prevent damage DO NOT

heat hubs beyond a maximum temperature of 400°F (205°C).
When an oxy-acetylene or blow torch is used, use an excess

acetylene mixture. Mark hubs near the center of their length in

several places on hub body with a temperature sensitive

crayon, 275°F (135°C) melt temperature. Direct flame towards

hub bore using constant motion to avoid overheating an area.

WARNING:

If an oil bath is used, the oil must have a flash

point of 350°F (177°C) or higher. Do not rest hubs on the

bottom of the container. Do not use an open flame in a

combustible atmosphere or near combustible materials.

Heat hubs as instructed above. Mount hubs as quickly as possible

with hub flange face flush with shaft end. Allow hubs to cool

before proceeding. Insert setscrews (if required) and tighten.

®

The Falk Corporation, P.O. Box 492, Zip 53201-0492

428-112

3001 W. Canal St., Zip 53208-4200, Milwaukee, WI USA Telephone: 414-342-3131

May 2000

Fax: 414-937-4359 e-mail: [email protected] web: www.falkcorp.com

Supersedes 12-98

Installation and Maintenance

Steelflex

®

Couplings

(Page 2 of 6)

Sizes 1150–1260 & 150–260

Types T10

TABLE 1 — General Purpose Greases

H

Ambient Temperature Range

0°F to 150°F

(-18°C to 66°C)

-30°F to 100°F

(-34°C to 38°C)

Manufacturer

Lubricant

Lubricant

Amoco Oil Co.

Amolith Grease #2

Amolith Grease #2

BP Oil Co.

Energrease LS-EP2

Energrease LS-EP1

Chevron U.S.A. Inc.

Dura-Lith EP2

Dura-Lith EP1

Citgo Petroleum Corp.

Premium Lithium Grease EP2 Premium Lithium Grease EP1

Conoco Inc.

EP Conolith Grease #2

EP Conolith Grease #2

Exxon Company, USA

Unirex N2

Unirex N2

E.F. Houghton & Co.

Cosmolube 2

Cosmolube 1

Imperial Oil Ltd.

Unirex N2L

Unirex N2L

Kendall Refining Co.

Lithium Grease L421

Lithium Grease L421

Keystone Div. (Pennwalt)

81 EP-2

81 EP-1

Lyondell Petrochemical (ARCO) Litholine H EP 2 Grease

Litholine H EP 2 Grease

Mobil Oil Corp.

Mobilux EP111

Mobilith AW1

Petro-Canada Products

Multipurpose EP2

Multipurpose EP1

Phillips 66 Co.

Philube Blue EP

Philube Blue EP

Shell Oil Co.

Alvania Grease 2

Alvania Grease 2

Shell Canada Ltd.

Alvania Grease 2

Alvania Grease 2

Sun Oil Co.

Ultra Prestige 2EP

Ultra Prestige 2EP

Texaco Lubricants

Starplex HD2

Multifak EP2

Unocal 76 (East & West)

Unoba EP2

Unoba EP2

Valvoline Oil Co.

Multilube Lithium EP Grease . . .

H

Grease application or re-lubrication should be done at temperatures above

20°F (–7°C). If grease must be applied below 20°F (–7°C), consult The Falk

Corporation.

Lubricants listed may not be suitable for use in the food processing industry;

check with lube manufacturer for approved lubricants.

(.pdf revision)

Summary of Contents for Steelflex T10

Page 1: ... specifications for general purpose and long term greases Because of its superior lubricating characteristics and low centrifuge properties Falk Long Term Grease LTG is highly recommended The use of general purpose grease requires re lubrication of the coupling at least annually Long Term Grease LTG The high centrifugal forces encountered in couplings separate the base oil and thickener of general...

Page 2: ...C using an oven torch induction heater or an oil bath To prevent damage DO NOT heat hubs beyond a maximum temperature of 400 F 205 C When an oxy acetylene or blow torch is used use an excess acetylene mixture Mark hubs near the center of their length in several places on hub body with a temperature sensitive crayon 275 F 135 C melt temperature Direct flame towards hub bore using constant motion to...

Page 3: ...ss to the gap specified in Table 2 Page 5 Insert bar as shown above to same depth at 90 intervals and measure clearance between bar and hub face with feelers The difference in minimum and maximum measurements must not exceed the ANGULAR INSTALLATION limits specified in Table 2 3 Offset Alignment Align so that a straight edge rests squarely or within the limits specified in Table 2 on both hubs as ...

Page 4: ... tightening torques of all fasteners 3 Inspect seal ring and gasket to determine if replacement is required If leaking grease replace 4 When connected equipment is serviced disassemble the coupling and inspect for wear Replace worn parts Clean grease from coupling and repack with new grease Install coupling using new gasket as instructed in this manual Periodic Lubrication The required frequency o...

Page 5: ...nd Float CPLG SIZE Installation Limits Operating Limits Cover Fastener Tightening Torque Values Allow Speed rpm Lube Wt Parallel Offset P Angular x y Normal Gap 10 Parallel Offset P Angular x y End Float Physical Limit Min 2 x F Max In Max mm Max In Max mm In mm Max In Max mm Max In Max mm In mm lb in Nm lb kg 1150T 012 305 016 406 250 6 024 610 062 1 57 620 15 7 650 73 4 1500 4 3 1 95 1160T 012 3...

Page 6: ...may cause premature failure and personal or property damage from flying debris The Falk Corporation P O Box 492 Zip 53201 0492 428 112 3001 W Canal St Zip 53208 4200 Milwaukee WI USA Telephone 414 342 3131 May 2000 Fax 414 937 4359 e mail falkinfo falkcorp com web www falkcorp com Supersedes 12 98 Installation and Maintenance Steelflex Couplings Page 6 of 6 Sizes 1150 1260 150 260 Types T10 PART N...