background image

3.7  

Governor

 

3.7.1 General 

The governor will normally require little servicing.  

Before proceeding with any inspection or servicing, TURN OFF THE GAS AT ISOLATING COCK. 

3.7.2 Procedure

 

Check and if necessary, clear air  breather hole of any  blockage. Ensure  valve  and seating  are clean 
and that diaphragm is in good condition.  

ALWAYS RE-CHECK GAS PRESSURE at test point after servicing governor.  

 

SECTION 4 - SPARES 

When ordering spare parts, ALWAYS quote appliance TYPE and SERIAL No.  This information can be found 
on the data badge.  A list of items available, together with codes, is as follows:- 
 

Description 

Part No. 

Plaque (single) 

531600010 

Thermocouple 

531600030 

Pilot burner body 

531600050 

Pilot orifice (Natural Gas) 

531600070 

Pilot orifice (Propane Gas) 

531600075 

Governor 

535900001 

Gas control 

537560020 

Knob for gas control 

535900000 

Disc for grid shelf handle 

531600410 

Handle for grid shelf 

531600420 

Grid shelf 

531620130 

Brander plate 

531620110 

Burner 

531600230 

Injector (Natural Gas) 

531600220 

Injector (Propane Gas) 

531600225 

X-Lighting burner 

531610150 

X-Lighting injector (Natural) 

531610140 

X-Lighting injector (Propane) 

531610145 

Drip trough 

531630140 

Brick support - centre 

531550130 

Brick support - end 

531540120 

 

Summary of Contents for G2522

Page 1: ...the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of the Applianc...

Page 2: ...on systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where...

Page 3: ...ied out 1 3 Ventilation The grill MUST be installed level in a well lit and draught free position Adequate ventilation whether natural or mechanical must be provided to ensure sufficient air for combu...

Page 4: ...ing or Flexible hose must not exceed 1 5m in length 1 5 Electrical Supply Not applicable to this appliance 1 6 Water Supply Not applicable to this appliance 1 7 Heat Inputs Natural I2h and Propane I3p...

Page 5: ...Unpack grill and check that all components are undamaged Parts supplied loose are specified in the contents list below Brander Drip Trough Brander Plate Grid Shelf Drip Tray Gas Governor Natural Gas o...

Page 6: ...Remove RH Side Panel b Fit a pressure gauge to test point and light grill c With burner at Full Flame position setting pressure should be as detailed in Section 1 9 On Natural gas models adjust gover...

Page 7: ...ng and pilot injectors Remove governor and check supply pressure accordingly section 1 9 Adjust aeration Adjust Low flame Turndown setting section 2 5 3 Change data plate To Convert from PROPANE to NA...

Page 8: ...1 To Remove Proceed as follows a Remove control knob and front facia panel bottom fixing nuts Pull facia panel lower edge forward then downwards to remove facia panel b Remove RH outer side panel view...

Page 9: ...und on the data badge A list of items available together with codes is as follows Description Part No Plaque single 531600010 Thermocouple 531600030 Pilot burner body 531600050 Pilot orifice Natural G...

Reviews: