FALCON
935-33400011
Inspection and Maintenance
Operators Manual
44
10.4
Yearly inspection
and maintenance check
1. The platform must go through an annual
inspection performed by a certifi ed aerial lift
company.
The annual inspection must check all lifting
and supporting devices, chassis etc. for wear
and tear or any defects. The platform must be
checked for loose wiring and any part that need
to be tightened or replaced due to normal wear
and tear, damage or manufacturers defect.
All inspections and repairs must be recorded
and kept in the machine fi le.
2. Lubrication according to the lubrication
diagram.
(See section 10.8)
3. Check that turret bearing bolts has torque
to specifi cations shown in the NM tabel.
4. Check all parts of the platform for
corrosion, cracks and other damages.
5. Control of the chains:
Wear on the chains must be controlled over 10
chain links.
By controlling the length between 11 spikes.
maximum allowable wear is 2% over 10 chain
links.
Chain groups
Nom. length
1 link (mm)
Nom. length
10 Links (mm)
Nom. length with
2% wear (mm)
½“ chain (12. series)
12.7
127
129.5
1 inch = 25.4 mm
Platform model
Bolts in outer
circle (top)
Bolts in inner
circle (buttom)
FS108Z
M16/215 Nm.
M16/215 Nm.
Nm Table