10.5
Inspection and maintenance
of stability system
To perform check of the stability system, a
scale, with a capacity at minimum 6600 lb, is
required. The minimum readout tolerance of
the scale shall be no more than 11 lb.
Place the scale under one of the outriggers.
See fi gure A.
The outriggers must be in standard position.
Raise the platform to inspection height 2 ft
Ttelescope out over the opposite outrigger
until the
red
lights at the outrigger at the scale
comes on.
(See fi gure B)
See table to see accurate allowed weight