Rev. Apr2 2020 ©
FALCON
Inspection and Maintenance
Operators manual
43
Inspection and maintenance
Perform inspection and maintenance for the
diesel engine (Option), generator (Option)
etc. according to the Operators/Maintenance
manual for these parts.
10.1
Daily inspection
and maintenance check
1. If the check should not be performed with
the following result, the platform may not be
used before all malfunctions are repaired.
2. With the outriggers lifted off the ground,
check that the
red
„Stability Indicator lights“
is on at all outriggers and the
red
“Stability
Indicator light”
at the Basket control panel
(Suppl. B) and at the Chassis control panel
(suppl. A) are on.
3. When the platform has been set up and
before operations start, please check that
when maximum outreach is achieved, one
or two of the
red
Stability Indicator light(s)
on the outrigger(s) comes on together with
the
“Stability Indicator light”
at the Basket
controlcpanel (Suppl. B) and at the Chassis
control panel (suppl. A), the only functions
free in this situation shall be
“RETRACT
TELESCOPE”
and
“MAIN BOOM UP”
until
the Stability Indicator lights are off .
4. Check the charge indicator for battery
state.
5. Check that the emergency stop disables
all functions of platform.
6. Check the platform for any defects such
as: damaged cables or chains, hydraulic leaks,
loose wiring, structural damage, damaged
basket mounting brackets, tire damage, etc.
10.2
Weekly inspection
and maintenance check
1. Tighten the crawler belts, according to
section 10.7.
2. Check bolts on axle locking plates
10.3
Monthly inspection
and maintenance check
1. Check the oil level in the hydraulic tank,
and refi ll as required.
2. Lubricating according to the lubrication
diagram.
3. Check all cylinders for tight fi t and the
valves and oil pipes for leaks.
4. Tighten the wheels according to the
specifi cation Nm.